Condenser

The condenser uses an external water source to cool down the steam and let it condense back into water, which gathers in the hotwell. The condenser has several devices:

  • 2 CARs (Condenser Air Removal), which are electric pumps which initially lower condenser pressure to allow MSIV to be opened.
  • 4 SJAE (Steam Jet Air Ejectors) which are used to eject uncondensable gasses from the condenser. Two of them should always be on when steam is available.