Notifications
You must be signed in to change notification settings - Fork 1
/
eventid_recv.vhd
157 lines (129 loc) · 4.32 KB
/
eventid_recv.vhd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
library ieee;
use ieee.std_logic_1164.all;
use ieee.numeric_std.all;
use work.helpers_std.all;
entity eventid_recv is
port(
CLK : in std_logic; -- must be 100 MHz!
--TIMER_TICK_1US_IN : in std_logic; -- 1 micro second tick, synchronous to CLK
-- Module inputs
SERIAL_IN : in std_logic; -- serial raw in, externally clock'ed at 12.5 MHz
ACK_IN : in std_logic; -- falling edge acknowledges receive of serial id
-- the external trigger id is sent on SERIAL_IN
EVENTID_OUT : out std_logic_vector(31 downto 0);
STATUS_OUT : out std_logic_vector(4 downto 0)
);
end entity;
--A2 trigger format of SERIAL_IN
--Startbit : "1"
--Trig.nr. : 32bit (but only ~20bit used at the moment)
--Paritybit : "0" or "1"
--Stopbit/Controlbit: "1"
--Parity check over trig Nr and parity bit
architecture arch1 of eventid_recv is
-- 500 us ticks
-- time until serial id must be acknowledged by falling ACK_IN
-- constant timeoutcnt_Max : integer := 500;
-- signal timeoutcnt : integer range 0 to timeoutcnt_Max := timeoutcnt_Max;
-- signal timer_tick_1us : std_logic;
--signal timeout_seen : std_logic := '0';
signal shift_reg : std_logic_vector(34 downto 0) := (others => '0');
signal bitcnt : integer range 0 to shift_reg'length;
signal reg_SERIAL_IN : std_logic;
signal done : std_logic;
signal data_eventid_reg : std_logic_vector(31 downto 0);
signal data_status_reg : std_logic_vector(4 downto 0);
signal ack_sync : std_logic;
signal ack_sync_old : std_logic;
signal id_recv : std_logic; -- high if "new" serial id has been received since last falling edge of ACK
type state_t is (IDLE, WAIT1, WAIT2, WAIT3, READ_BIT, WAIT5, WAIT6, WAIT7, WAIT8, FINISH);
signal state : state_t := IDLE;
begin
-- timer_tick_1us <= TIMER_TICK_1US_IN;
-- since CLK runs at 100 MHz, we sample at 12.5MHz due to 8 WAIT states
PROC_FSM : process
begin
wait until rising_edge(CLK);
-- synchronize inputs
ack_sync <= ACK_IN;
ack_sync_old <= ack_sync;
reg_SERIAL_IN <= SERIAL_IN;
-- use the falling edge of ACK as an
-- reset of the serial event id receiver
-- if this happens during serial receive, it might again try to
-- receive an id, but then the error flag is due to a missing stop bit
if ack_sync = '0' and ack_sync_old = '1' then
state <= IDLE;
shift_reg <= (others => '0');
id_recv <= '0';
else
case state is
when IDLE =>
-- wait until a start bit is seen
if reg_SERIAL_IN = '1' then
done <= '0';
bitcnt <= shift_reg'length;
state <= WAIT1;
else
-- else we're done by default
done <= '1';
end if;
when WAIT1 =>
state <= WAIT2;
when WAIT2 =>
state <= WAIT3;
when WAIT3 =>
state <= READ_BIT;
when READ_BIT =>
-- actually WAIT4, but we read here, in the middle of
-- the serial line communication (hopefully safest point to sample)
bitcnt <= bitcnt - 1;
-- we fill the shift_reg LSB first since this way the trg id arrives
shift_reg <= reg_SERIAL_IN & shift_reg(shift_reg'high downto 1);
state <= WAIT5;
when WAIT5 =>
-- check if we're done reading
if bitcnt = 0 then
state <= FINISH;
else
state <= WAIT6;
end if;
when WAIT6 =>
state <= WAIT7;
when WAIT7 =>
state <= WAIT8;
when WAIT8 =>
state <= WAIT1;
when FINISH =>
-- wait until serial line is idle again
if reg_SERIAL_IN = '0' then
state <= IDLE;
id_recv <= '1';
end if;
end case;
end if;
end process;
STATUS_OUT <= data_status_reg;
EVENTID_OUT <= data_eventid_reg;
PROC_REG_INFO : process
begin
wait until rising_edge(CLK);
data_status_reg <= (others => '0');
data_eventid_reg <= (others => '0');
if done = '1' then
data_eventid_reg <= shift_reg(32 downto 1);
data_status_reg(1) <= shift_reg(0);
data_status_reg(2) <= xor_all(shift_reg(33 downto 1));
data_status_reg(3) <= shift_reg(34);
data_status_reg(4) <= id_recv;
-- check if start and control bit is 1 and parity is okay
if shift_reg(34) = '1' and shift_reg(0) = '1' and xor_all(shift_reg(33 downto 1)) = '0' then
-- set error flag low
data_status_reg(0) <= '0';
else
-- set error flag high
data_status_reg(0) <= '1';
end if;
end if;
end process;
end architecture;