from Doberman import Sensor
import u12
class labjack(Sensor):
"""
Labjack U12. Has a very different interface, so we don't inherit from more
than Sensor
"""
def SetParameters(self):
self.then = 0
self.read_args = {'idNum' : None, 'demo' : 0}
self.reading_commands = dict(zip(self.reading_names,
self.reading_names))
def OpenDevice(self):
self._device = u12.U12()
self.generic_read = {
'analog' : self.AnalogRead,
'digital' : self.DigitalRead,
'counter' : self.CounterRead,
}
return True
def Setup(self):
self.then = self._device.eCount(resetCounter=1)['ms']
def AnalogRead(self, channel):
return self._device.eAnalogIn(channel=channel, gain=0,
**self.read_args)['voltage']
def DigitalRead(self, channel):
return self._device.eDigitalIn(channel=channel, readD=0,
**self.read_args)['state']
def CounterRead(self, *args):
count = self._device.eCount(resetCounter=1)
return count['counts'], count['ms']
def NTCtoTemp(self, val):
resistance = self.rc[0]*val/(self.rc[1] + self.rc[2]*val)
temp = sum([v*resistance**i for i,v in enumerate(self.tc)])
return temp
def ProcessOneReading(self, name, data):
if name == 'mv_freq': # bias voltage
counts, now = data
if now == self.then:
return -1
val = counts/(now - self.then)*1000
self.then = now
return val
if name == 'box_temp':
return self.NTCtoTemp(data)
return data
def SendRecv(self, message, dev):
"""
We use "message" here to mean the reading name
"""
ret = {'retcode' : 0, 'data' : None}
try:
temp = self.reading_templates[message]
ret['data'] = self.generic_read[temp['type']](temp['channel'])
except Exception as e:
self.logger.error(f'Caught a {type(e)}: {e}')
ret['retcode'] = -2
return ret