HDD calculation #106

Open
FedericoTartarini opened this issue Sep 7, 2021 · 10 comments
Open

HDD calculation #106

FedericoTartarini opened this issue Sep 7, 2021 · 10 comments
Assignees
Labels
bug Something isn't working High Priority This is High Priority!

Comments

@FedericoTartarini
Copy link
Contributor

For Bologna, I do not think our results match the climate.onebuilding results.

HDD for 10°C baseline with our tool = 730
HDD for 10°C baseline Onebuilding = 673

image

image
from this file
bologna.txt

@FedericoTartarini FedericoTartarini added bug Something isn't working High Priority This is High Priority! labels Mar 17, 2023
@Ericlee0128 Ericlee0128 self-assigned this Mar 20, 2023
@Ericlee0128
Copy link
Contributor

@FedericoTartarini
Hi Federico, to verify that Bologna's HDD calculations were accurate. I went to Climate.OneBuilding. Org, downloaded the Bologna EPW and opened the CBE Clima tool and uploaded this EPW file and I calculated the total HDD results. Then, on this CBE Clima tool, I selected the Bologna EPW file and again calculated the results for the total HDD. I compared these two results and found them both to be the same. I would like to check with you if this has been solved, thanks!

Snipaste_2023-04-10_19-58-46

Snipaste_2023-04-10_20-03-34

@FedericoTartarini
Copy link
Contributor Author

I apologize for not making this 100% clear, but unfortunately, this is not the issue I was mentioning.

The issue is that if you open the .zip climateorg file you downloaded with from here, inside there is a file with ends with stat (ITA_ER_Bologna-Marconi.AP.161400_TMYx.stat).

Open this file with either NotePad or Excel you will find a table in it showing the heating degree day.

image

This is the value that does not match the results of the Clima tool. Please let me know if this is clear now.

@Ericlee0128
Copy link
Contributor

I apologize for not making this 100% clear, but unfortunately, this is not the issue I was mentioning.
The issue is that if you open the .zip climateorg file you downloaded with from here, inside there is a file with ends with stat (ITA_ER_Bologna-Marconi.AP.161400_TMYx.stat).
Open this file with either NotePad or Excel you will find a table in it showing the heating degree day.
image
This is the value that does not match the results of the Clima tool. Please let me know if this is clear now.

Hi Federico, thanks for the explanation, I misunderstood it a bit before. I would like to double check, I noticed that the STAT file has two HDDs "Monthly Standard Heating/Cooling Degree Days/Hours" and "Monthly Weather File Heating/Cooling Degree Days/Hours", which one should I use. Thanks!

@FedericoTartarini
Copy link
Contributor Author

Very good point. Thank you for noticing this. I do not know what is the difference between the two. It would be amazing if you could look into it and let me know if you find the reason they provide to sets of values.

@danielh7-cs9
Copy link
Contributor

danielh7-cs9 commented Apr 12, 2023

I believe there are two HDD value sets based on the following which is stipulated in the stat file.
The "Monthly Standard Heating/Cooling Degree Days/Hours" values are being calculated off the 2021 ASHRAE design conditions.
image

Where as the "Monthly Weather File Heating/Cooling Degree Days/Hours" HDD values are solely calculated off the weather data source.

image

@FedericoTartarini
Copy link
Contributor Author

Great, so I then believe we should compare our results with the Monthly Weather File Heating since we only have access to this dataset.

@danielh7-cs9
Copy link
Contributor

Hey @FedericoTartarini, Eric and I have been wrapping our heads around quite a bit, but so far are unable to identify where the calculation error may be with the clima code:
image

I've researched but I am unable to ascertain the formula climate.onebuilding is using to calculate the HDD and CDD values.

@FedericoTartarini
Copy link
Contributor Author

Thank you for looking into this. @giobetti shall we contact Dru and ask him if he knows how these values are calculated in the OneBuilding files?

@danielh7-cs9
Copy link
Contributor

Thank you for looking into this. @giobetti shall we contact Dru and ask him if he knows how these values are calculated in the OneBuilding files?

Hi Federico, just checking if you've received any response here?

@FedericoTartarini
Copy link
Contributor Author

No unfortunately.

@t-kramer t-kramer self-assigned this Mar 21, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working High Priority This is High Priority!
Projects
None yet
Development

No branches or pull requests

5 participants