Notifications
You must be signed in to change notification settings - Fork 0
/
par_measure.m
309 lines (273 loc) · 16.1 KB
/
par_measure.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
%Author: Dimme de Groot
%Date: May 2024
%Descr: This class implements the perceptual distortion measure as described in [1]. I refer to this distortion measure as the Par-measure, after the first author.
% Some more details can be found in [2, 3, 4, 5]
%
%Usage: Initialize the class as:
% Par_measure = par_measure(Fs, Tframe, x_ref, x_dB_ref, F_cal, Ng)
% Compute the masking curve and weighting curves as:
% [maskcurve, maskcurve_spl, p_par] = par_measure.comp_maskcurve(masker)
% In some scenarios, it might be convenient to set all values of p_par below a certain frequency high. In that case you can use
% [maskcurve, maskcurve_spl, p_par] = par_measure.comp_maskcurve(masker, false, threshold)
% with threshold the frequency value below which p_par is set high
% Plot the masking curve as:
% Par_measure.plot_maskcurve(masker)
% Plot the masking curve and the disturbance as
% Par_measure.plot_maskcurve(masker, disturbance)
% Compute the digital representation amplitude given a physical representation amplitude (in dB SPL) and vice versa using:
% amplitude_digital = Par_measure.physical_to_digital(amplitude_physical)
% amplitude_physical = Par_measure.digital_to_physical(amplitude_digital)
%
%Inputs: Fs: [Hz], sample frequency
% Tframe: [s], the time of the zero-padded segmentation window (typically 20 to 40 ms)
% x_ref: [-], a reference digital value for which you know the sound pressure level (for example, x_ref = 1)
% x_dB_ref: [dB SPL], the corresponding sound pressure level (for example, x_dB_ref = 70)
% F_cal: [Hz], a calibration frequency. (typically 1000 Hz)
% Ng: [-], the number of gammatone filters used. (typically 32 to 64)
%
% masker: the discrete time-domain signal (masker) of length Nframe
% disturbance: the discrete time-domain signal (distrubance) of length Nframe, optional!
% threshold: the threshold [Hz] below which the values of p_par should be set high artificially.
%
%Outputs: maskcurve: [-], the double sided masking curve. I dont really know a scenario where this one is usefull to view
% maskcurve_spl: [dB SPL], the single sided masking curve in dB SPL
% p_par: [-], 1/maskcurve. To compute the par measure, you use ||diag(p_par)*epsilon||_2^2, with epsilon the freq. domain disturbance
%
%Sources:
%[1] Van de Par et al. A perceptual model for sinusoidal audio coding based on spectral integration, 2005. https://doi.org/10.1155/ASP.2005.1292
%[2] de Groot. A heuristic approach to spatial audio using consumer loudspeaker systems (appendix D, E, F), 2023. http://resolver.tudelft.nl/uuid:ee669571-b15a-4f0d-99cd-4c6c35acbd45
%[3] C. Taal. Prediction and Optimization of Speech Intelligibility in Adverse Conditions. PhD thesis. https://doi.org/10.4233/uuid:407c0a83-25c1-4cb3-ab4c-5a691d19f949
%[4] B. R. Glasberg and B. C. Moore, "Derivation of auditory filter shapes from notched-noise data,” Hearing Research, vol. 47, no. 1, pp. 103–138, 1990.
%[5] N. de Koeijer. Sound Zones with a Cost Function based on Human Hearing (appendix A), 2021. http://resolver.tudelft.nl/uuid:4e66fb60-2350-4010-867a-53c08a0177a7
%[6] G. Charestan et al. A Gammatone-based Psychoacoustical Modeling Approach for Speech and Audio Coding, 2001. https://www.researchgate.net/publication/2884296_A_Gammatone-based_Psychoacoustical_Modeling_Approach_for_Speech_and_Audio_Coding
%
%Remarks:
% There are some parts of the code where I'm not really happy with. For example, I have a weird factor of two in the computation of the masking curve.
% This is likely all resolvable by changing the calibration procedure and tracking the FFT normalisations better.
% Anyway, through comparison with the plots in [1] and by listening to signals predicted to have an inaudible or only slightly audible distortion,
% I feel like the implementation is at least mostly correct and usefull as a predictor of distortions.
classdef par_measure
properties
Fs %[Hz], sample frequency
Tframe %[s], the time of the zero-padded segmentation window
x_ref %[-], the reference value in digital domain
x_dB_ref %[dB SPL] the reference value in physical domain
F_cal %[Hz], the calibration frequency
Ng %[-], the number of gammatone filters used
Nframe %[-], the number of samples per window --> obtained from Tframe, even number
freq_ax %[Hz], the frequency axis
alpha_ov_p0 %[-], a constant useful in calculating the SPL in dB
h_hat_om %[-], the outer middle ear filter (misleading! it is the inverse of the threshold in quiet) used in Par
h_hat_gamma %[-], the gammatone filter used in Par
c %[c1, c2] [-], the calibration constants used in Par
end
methods
function obj = par_measure(Fs, Tframe, x_ref, x_dB_ref, F_cal, Ng)
if nargin == 0
obj.Fs = 48000;
obj.Tframe = 0.4;
obj.x_ref = 1;
obj.x_dB_ref = 70;
obj.F_cal = 1000;
obj.Ng = 64;
else
obj.Fs = Fs;
obj.Tframe = Tframe;
obj.x_ref = x_ref;
obj.x_dB_ref = x_dB_ref;
obj.F_cal = F_cal;
obj.Ng = Ng;
end
obj.Nframe = methodNframe(obj);
obj.freq_ax = methodFreq_ax(obj);
obj.alpha_ov_p0 = methodAlpha_ov_p0(obj);
obj.h_hat_om = methodH_hat_om(obj);
obj.h_hat_gamma = methodH_hat_gamma(obj);
obj.c = methodC(obj);
end
%Calculate number of samples/frame
function Nframe = methodNframe(obj)
Nframe = round(obj.Fs*obj.Tframe/2)*2;
disp("The distortion measure expects frames of " + num2str(Nframe) + " samples")
end
%calculate frequency axis in [0, Fs/2]
function freq_ax = methodFreq_ax(obj)
k = 0:obj.Nframe/2;
freq_ax = k*obj.Fs/obj.Nframe;
end
%Needed for conversion from digital to SPL [2, Appendix F], [5, Appendix A]
function alpha_ov_p0 = methodAlpha_ov_p0(obj)
alpha_ov_p0 = 10^((obj.x_dB_ref - 20*log10(obj.x_ref))/20);
end
%The outer middle ear filter of Par. [3, p. 23]. Note that this is just the threshold in quiet
function h_hat_om = methodH_hat_om(obj)
f = abs(obj.freq_ax); %Note: equation only holds for nonnegative
Tq = 3.64*(f/1000).^(-0.8)-6.5*exp(-0.6*(f/1000-3.3).^2)+10^(-3)*(f/1000).^4; %Threshold in quit [dB SPL]
Tq = Tq - 20*log10(obj.alpha_ov_p0); %Go from dB SPL to dB
h_hat_om = 10.^-(Tq/20); %From dB to ampltiude
end
%The Gammatone filters [1], [4]
function h_hat_gamma = methodH_hat_gamma(obj)
nu = 4; %the filter order
kappa = 2^(nu-1)*factorial(nu-1)/(pi*dfac(2*nu-3)); %normalisation term
fc = spacing(obj.Fs, obj.Ng); %spacing between the different center frequencies of the gammatone filters
f = abs(obj.freq_ax);
h_hat_gamma = zeros(obj.Ng, obj.Nframe/2+1); %single-sided
ERB = @(f) 24.7*(4.37*f/1000+1); %see [4]
for ng=1:obj.Ng
h_hat_gamma(ng,:) = (1+((f-fc(ng))/(kappa*ERB(fc(ng)))).^2 ).^(-nu/2); %see [4]
end
function out = dfac(in) %double factorial
out = 1;
if mod(in,2) == 0
for i=2:2:in
out = out*i;
end
else
for i=1:2:in
out = out*i;
end
end
end
function fc = spacing(Fs, Ng)
E_0 = 0.0; %
E_Fs = 21.4*log10(4.37*Fs/2000 + 1); %Fs/2
E = linspace(E_0, E_Fs, Ng);
fc = 1000/4.37 * (10.^(E/21.4) - 1);
end
end
%Calibration constants [1], [6].
%Note: if i recall correctly, the proof in [6] is incorrect: the calibration might not converge if you pick the wrong frequency
%Namely, the lim C1-->infty F(C1) after eq. 6 misses a -1: thus, F(C1-->infty) could be smaller than zero, in which case the biseciton method does not converge
function c = methodC(obj)
%find the amplitudes required for calibration
A_52 = 10^(52/20)/obj.alpha_ov_p0;
A_70 = 10^(70/20)/obj.alpha_ov_p0;
%find the filters associated with f_1 and f_2 (which are the same in this implementation)
[M, Indx] = min(abs(obj.freq_ax - obj.F_cal));
disp("Calibration frequency offset: " + num2str(M) + " Hz")
h_hat_gamma_f1 = obj.h_hat_gamma(:,Indx);
h_hat_om_f1 = obj.h_hat_om(Indx);
h_hat_gamma_f2 = h_hat_gamma_f1;
h_hat_om_f2 = h_hat_om_f1;
%Some terms which can be precalculated
Term1 = sum(h_hat_gamma_f1.^2);
Term2 = A_70^2*h_hat_om_f2^2/obj.Nframe;
Term3 = A_52^2*h_hat_om_f2^2;
%Bisection Method:
tol = 1e-15;
f_c2t = 2*tol;
c2_l = 0; %inital guess
c2_r = 10; %initial guess
f_c2l = fnc_f_c2(c2_l, Term1, Term2, Term3, h_hat_gamma_f2);
f_c2r = fnc_f_c2(c2_r, Term1, Term2, Term3, h_hat_gamma_f2);
if f_c2l*f_c2r > 0
disp('ABORT: solution not in guessed interval. You can fix this by increasing c2_r, though it is more likely that a weird calibration frequency is used')
else
while abs(f_c2t)>tol
c2_t = (c2_l+ c2_r)/2;
f_c2t = fnc_f_c2(c2_t, Term1, Term2, Term3, h_hat_gamma_f2) ;
if f_c2t*f_c2l < 0
c2_r = c2_t;
f_c2r = f_c2t;
else
c2_l = c2_t;
f_c2l = f_c2t;
end
end
end
c2 = c2_t;
c1 = c2/obj.Nframe * Term1;
c = [c1, c2];
function f_c2 = fnc_f_c2(c2, Term1, Term2, Term3, h_hat_gamma_f2)
f_c2 = c2*sum( Term3*h_hat_gamma_f2.^2 ./ (Term2*h_hat_gamma_f2.^2 + c2*Term1) )-1;
end
end
%Functions for users of the measure
function [maskcurve, maskcurve_spl, p_par] = comp_maskcurve(obj, x, flag_low_freq, threshold)
if nargin == 2
flag_low_freq = true;
end
if nargin == 3 && ~flag_low_freq
threshold = 30;%Hz
[~, INDXthresh] = min(abs(obj.freq_ax-threshold));
end
if nargin == 4 && ~flag_low_freq
[~, INDXthresh] = min(abs(obj.freq_ax-threshold));
end
x = x(:).'; %ensure row
x_hat = fft(x)/length(x);
%find g^2
x_hat = 2*x_hat(1:obj.Nframe/2+1); %convert to single sided
tmp = zeros(1,obj.Nframe/2+1);
for i = 1:obj.Ng
num = obj.h_hat_om.^2.*obj.h_hat_gamma(i,:).^2;
den = norm(x_hat.*obj.h_hat_om.*obj.h_hat_gamma(i,:))^2/obj.Nframe+obj.Nframe*obj.c(1);
tmp = tmp+num./den;
end
gsqr_SS = obj.c(2)*tmp; %=g^2, single sided
gsqr_DS = 2*[gsqr_SS, fliplr(gsqr_SS(2:end-1))]; %=g^2, double sided (times 2, huh!)
p_par = sqrt(gsqr_DS)/(obj.Nframe); %The division by obj.Nframe is needed due to FFT stuff. It could also be part of the calibration procedure.
maskcurve = 1./sqrt(gsqr_DS); %DOUBLE SIDED, [-]
maskcurve_spl = 20*log10(1./sqrt(gsqr_SS))+20*log10(obj.alpha_ov_p0); %SINGLE SIDED, [dB SPL]
%Artificially set weights for low frequencies high (i.e. discourage disturbances in low frequencies
if ~flag_low_freq
val = max(p_par);
if INDXthresh ~= 0
p_par(1:INDXthresh) = 100*val;
p_par(end-INDXthresh+2:end) = 100*val;
end
end
end
function A_digital = physical_to_digital(obj, A_SPL) %digital <--> physical representation
%Function to go from a physical sound level (dB SPL) to a digital representation %
A_digital = 10^(A_SPL/20)/obj.alpha_ov_p0;
end
function A_physical = digital_to_physical(obj, A_digital) %digital <--> physical representation
%Function to go from a physical sound level (dB SPL) to a digital representation %
A_physical = 20*(log10(abs(A_digital))+log10(obj.alpha_ov_p0));
end
function plot_maskcurve(obj, masker, disturbance)
if nargin == 2
dist_flag = 0;
else
dist_flag = 1;
end
f = obj.freq_ax;
Tq = 3.64*(f/1000).^(-0.8)-6.5*exp(-0.6*(f/1000-3.3).^2)+10^(-3)*(f/1000).^4; %Threshold in quit [dB SPL]
[~, maskcurve_spl, ~] = comp_maskcurve(obj, masker); %masking curve [dB SPL]
masker = 2*abs(fft(masker))/obj.Nframe; %masker, single sided
masker = masker(1:length(maskcurve_spl)); %" "
mask_SPL = 20*log10(masker*obj.alpha_ov_p0); %to dB SPL
if dist_flag == 1
disturbance = 2*abs(fft(disturbance))/obj.Nframe; %disturbance, single sided
disturbance = disturbance(1:length(maskcurve_spl)); %" "
dist_SPL = 20*log10(disturbance*obj.alpha_ov_p0); %" "
figure
semilogx(obj.freq_ax, Tq, 'linewidth', 2)
hold on
semilogx(obj.freq_ax, maskcurve_spl, 'linewidth', 2, 'linestyle', '--')
semilogx(obj.freq_ax, mask_SPL)
semilogx(obj.freq_ax, dist_SPL)
grid on
legend('Threshold in quiet', 'Masking curve', 'Masker', 'Disturbance')
xlabel('Frequency [Hz]')
ylabel('Magnitude [dB SPL]')
ylim([-10 100])
xlim([50 16000])
else
figure
semilogx(obj.freq_ax, Tq, 'linewidth', 2)
hold on
semilogx(obj.freq_ax, maskcurve_spl, 'linewidth', 2, 'linestyle', '--')
semilogx(obj.freq_ax, mask_SPL)
grid on
legend('Threshold in quiet', 'Masking curve', 'Masker')
xlabel('Frequency [Hz]')
ylabel('Magnitude [dB SPL]')
ylim([-10 100])
xlim([50 16000])
end
end
end
end