Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathsimulate_model.m
147 lines (127 loc) · 2.43 KB
/
simulate_model.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
clear all; close all; clc;
%% constants
% simulation time
sim_time=10000;%seconds
sim_step=1; %second
% Actuator subsystem 1
a_1= 0.107;
b_1=26.59;
c_1=-0.97;
% Actuator subsystem 2
a_2= 0.107;
b_2=26.59;
c_2=-0.97;
% Actuator subsystem 3
a_3= 0.107;
b_3=26.59;
c_3=-0.97;
% Actuator subsystem 4
a_4= 0.107;
b_4=26.59;
c_4=-0.97;
% Tank base area
A1=pi*(36/2)^2; %cm^2
A2=pi*(36/2)^2; %cm^2
A3=pi*(36/2)^2; %cm^2
A4=pi*(36/2)^2; %cm^2
%% Initial conditions
h10=21; % cm
h20=20; % cm
h30=17; % cm
h40=19; % cm
q10=0; % cm^3/sec
q20=0; % cm^3/sec
q30=0; % cm^3/sec
q40=0; % cm^3/sec
%% Fault parameters
% Leakage fault function
theta_p_1=0.0; %tank 1
theta_p_2=0; %tank 2
theta_p_3=0.0; %tank 3
theta_p_4=0; %tank 4
% Leakage fault times
%tank-1
t_p_1_1=4000;
t_p_1_2=5000;
%tank-2
t_p_2_1=2000;
t_p_2_2=3000;
%tank-3
t_p_3_1=2000;
t_p_3_2=3000;
%tank-4
t_p_4_1=2000;
t_p_4_2=3000;
% Actuator fault function
theta_a_1=0.0; %tank 1
theta_a_2=0; %tank 2
theta_a_3=0; %tank 3
theta_a_4=0; %tank 4
% Actuator fault times
%tank-1
t_a_1_1=5500;
t_a_1_2=6300;
%tank-2
t_a_2_1=1000;
t_a_2_2=2000;
%tank-3
t_a_3_1=1000;
t_a_3_2=2000;
%tank-4
t_a_4_1=1000;
t_a_4_2=2000;
% Sensor fault function
theta_s_1=0; %tank 1
theta_s_2=0; %tank 2
theta_s_3=0; %tank 3
theta_s_4=0; %tank 4
theta_s_1_2=0.0; % offset tank 1
theta_s_2_2=0; % offset tank 2
theta_s_3_2=0; % offset tank 3
theta_s_4_2=0; % offset tank 4
% Sensor fault times (sec)
%tank-1
t_s_1_1=1000;
t_s_1_2=2000;
%tank-2
t_s_2_1=2000;
t_s_2_2=3000;
%tank-3
t_s_3_1=2000;
t_s_3_2=3000;
%tank-4
t_s_4_1=2000;
t_s_4_2=3000;
%% Demand pattern
load dataset
g=9.80; %m/s^2
% measured consumption
s1=dataset{1, 1}{5, 2}; s1=fillmissing(s1,'nearest');
s2=dataset{1, 1}{6, 2}; s2=fillmissing(s2,'nearest');
s3=dataset{1, 1}{7, 2}; s3=fillmissing(s3,'nearest');
s4=dataset{1, 1}{8, 2}; s4=fillmissing(s4,'nearest');
% consumption using demand valve setting
% s1=dataset{1, 4}{8, 2}; s1=fillmissing(s1,'previous');
% s2=dataset{1, 4}{9, 2}; s2=fillmissing(s2,'previous');
% s3=dataset{1, 4}{10, 2}; s3=fillmissing(s3,'previous');
% s4=dataset{1, 4}{11, 2}; s4=fillmissing(s4,'previous');
% orifice size parameter
gamma_1=2.5;
gamma_2=2.5;
gamma_3=2;
gamma_4=2;
%% PLC parameters
% Minimum and maximum thresholds of tanks (cm)
Ru_1=30;
Rl_1=20;
Ru_2=30;
Rl_2=16;
Ru_3=22;
Rl_3=16;
Ru_4=22.7;
Rl_4=15.9;
%% Simulate model and save data
sim WaterSafe.mdl
save('simdata', 'ans')
%% Compare real with simulated data
run compare_data.m