Hello everyone!

I suspect that the documentation on the absorption coefficient of building wall is wrong.

It is documented as follows:
"Description: Wall absorption coefficient [0,1] (between 0 : “fully absorbent” and 1 : “fully reflective”)".
However, the absorption coefficient of 0 means fully reflecting and 1 means fully absorbing.

The calculation results show higher sound levels when the coefficient is low, so I think modification is necessary just regarding the documentation.

Please confirm this.

Thanks.

@jtagusari jtagusari added the bug label Oct 12, 2023
@nicolas-f
Copy link
Member

Hi,

Thanks for the feedback

Yes the documentation is wrong.

The default value is 0.1, it is hard wall, so there is little absorption.

0 is fully reflective and 1 fully absorbing.