Skip to content

Latest commit

 

History

History
276 lines (220 loc) · 13.7 KB

CHANGELOG.md

File metadata and controls

276 lines (220 loc) · 13.7 KB

Changelog

All notable changes to this project will be documented in this file.

The format is based on Keep a Changelog, and this project adheres to Semantic Versioning.

Changelog

[3.3.0] November 28 2021

Added

  • Add system commands for syslog level and watch #98
  • Added pool data to telegrams 0x494 & 0x495 #102
  • Add RC300 second summermode telegram #108
  • Add support for the RC25 thermostat #106
  • Add new command 'entities' for a device, e.g. http://ems-esp/api/boiler/entities to show the shortname, description and HA Entity name (if HA enabled) #116
  • Support for Junkers program and remote (fb10/fb110) temperature
  • Home Assistant state_class attribute for Wh, kWh, W and KW #129
  • Add current room influence for RC300 #136
  • Added Home Assistant device_class to sensor entities
  • Added another Buderus RC10 thermostat with Product ID 65 #160
  • Added support for mDNS #161
  • Added last system ESP32 reset code to log (and system info output)
  • Firmware Checker in WebUI #168
  • Added new MQTT setting for enabling 'response' topic
  • Support for non-standard Thermostats like Tado #174
  • Include MQTT connection status in 'api/system/info'
  • Include Network status in 'api/system/info' and also the MQTT topic info #202
  • Added Ethernet PHY module as an option in the Board Profile #210

Fixed

  • MQTT reconnecting after WiFi reconnect #99
  • Manually Controlling Solar Circuit #107
  • Fix thermostat commands not defaulting to the master thermostat #110
  • Enlarge parse-buffer for long names like cylinderpumpmodulation
  • MQTT not subscribing to all device entities #166
  • Help fix issues with WebUI unable to fully load UI over Ethernet #177
  • Shower alert never reset after limit reached when enabled [(PR #185)]
  • Remove HA entity entries when a device value goes dormant #196
  • deciphering last error code dates on 0xC2 telegram #204

Changed

  • Syslog BOM only for utf-8 messages #91
  • Check for KM200 by device-id 0x48, remove tx-delay #90
  • rename fastheatupfactor to fastheatup and add percent #122
  • "unit" renamed to "uom" in API call to recall a Device Value
  • initial backend React changes to replace the class components (HOCs) with React Hooks
  • Use program-names instead of numbers
  • Boiler's maintenancemessage always published in MQTT (to prevent HA missing entity)
  • Unit of Measure 'times' added to MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes
  • Improved API. Restful HTTP API works in the same way as MQTT calls
  • Removed settings for MQTT subscribe format #173
  • Improve Nefit Moduline 200 functionality #183
  • status in the MQTT heartbeat renamed to bus_status
  • Layout changes in the WebUI, showing stripped table rows in Dashboard
  • Alternative font for log window #219

BREAKING CHANGES

  • API: "unit" renamed to "uom" in API call to recall a Device Value
  • HA: sensor.boiler_boiler_temperature renamed to sensor.actual_boiler_temperature
  • HA: binary_sensor.boiler_ww_disinfecting renamed to binary_sensor.boiler_ww_disinfection
  • HA: # removed from counts in MQTT Fails, Rx fails, Rx received, Tx fails, Tx reads & Tx writes
  • txread renamed to txreads and txwrite renamed to txwrites in MQTT heartbeat payload
  • 'dallas sensors' in api/system/info moved to the "System" section. Renamed "uptime (seconds)" and "reset reason"
  • status in the MQTT heartbeat renamed to bus_status

[3.2.1] August 8 2021

Added

  • json body in API can now take device, name, cmd, hc and id
  • added example of how to use API directly to control values from Home Assistant
  • API calls are shown in debug log (For troubleshooting)

Fixed

  • fixed issue with Home Assistant entity naming where boiler's ww was duplicated in entity name
  • fixed issue where wwSetTemp was written too instead of wwSelTemp

Changed

  • fixed case on mqtt names, like 'wwtankmiddletemp'
  • renamed Product ID to 'EMS Product ID' in Home Assistant
  • removed brackets around tags, e.g. (hc1) selected room temperature" is now just "hc1 selected room temperature"

[3.2.0] August 6 2021

Added

  • support for IPv6 (web/api/mqtt, not syslog yet) #83
  • System Log in Web UI will show current time if the NTP Service is enabled #82
  • Network settings for Tx-power, WiFi-bandwidth, WiFi-sleepmode #83
  • optional low CPU clockrate (160 MHz) #83
  • select format for enumerated values in web
  • settings for water hysteresis on/off
  • dallas sensor name editable. sensorname console-command, replace sensorid with a unique name #84
  • 'restart' system command. Can be invoked via API with authentication. #87
  • add Download button in Web UI for log

Fixed

  • set mode allow numbers
  • Junkers thermostat shows mode as selected by set_mode
  • HA thermostat mode if bool-format: numbers is selected
  • Web UI System Log sometimes skipped a few log messages when watching real-time
  • fix wwactivated #89
  • don't show commands (like reset) as Device values in the Web or Console

Changed

  • removed Rx echo failures counting as incomplete telegrams. Bad telegrams show as Warning and not Errors. #80
  • add upload_sec to api/system/info and removed # from some names to keep consistent with MQTT heartbeat
  • added debug target to PlatformIO build to help hunt down system crashes
  • enumerated values always start at zero
  • maintenance settings for time/date as extra setting
  • move api/mqtt formats to settings, add enum format
  • UI improvements for editing Dallas Sensor details
  • RESTful GET commands can also require authentication (via bearer access token) for better security
  • Updated AsyncMqttClient to 0.9.0 and ArduinoJson to 6.18.3
  • Download buttons for settings and info under the Help tab

[3.1.1] June 26 2021

Added

  • new command called commands which lists all available commands. ems-esp/api/{device}/commands
  • More Home Assistant icons to match the UOMs
  • new API. Using secure access tokens and OpenAPI standard. See doc/EMS-ESP32 API.md and #50
  • show log messages in Web UI #71

Fixed

  • HA thermostat mode was not in sync with actual mode #66
  • Don't publish rssi if Wifi is disabled and ethernet is being used
  • Booleans are shown as true/false in API GETs

Changed

  • info command always shows full names in API. For short names query the device or name directly, e.g. http://ems-esp/api/boiler
  • free memory is shown in kilobytes
  • boiler's warm water entities have ww added to the Home Assistant entity name #67
  • improved layout and rendering of device values in the WebUI, also the edit value screen

[3.1.0] May 4 2021

Added

  • Mock API to simulate an ESP, for testing web
  • Able to write values from the Web UI
  • check values with "cmd":<valuename> and data empty or ?
  • set hc for values and commands by id or prefix hc<x>+separator, separator can be any char

Fixed

  • Don't create Home Assistant MQTT discovery entries for device values that don't exists (#756 on EMS-ESP repo)
  • Update shower MQTT when a shower start is detected
  • S32 board profile

Changed

  • Icon for Network
  • MQTT Formatting payload (nested vs single) is a pull-down option
  • moved mqtt-topics and texts to local_EN, all topics lower case
  • Re-enabled Shower Alert (still experimental)
  • lowercased Flow temp in commands
  • system console commands to main

[3.0.1] March 30 2021

Added

  • power settings, disabling BLE and turning off Wifi sleep
  • Rx and Tx counts to Heartbeat MQTT payload
  • ethernet support
  • id to info command to show only a heatingcircuit
  • add sending devices that are not listed to 0x07
  • extra MQTT boolean option for "ON" and "OFF"
  • support for chunked MQTT payloads to allow large data sets > 2kb
  • external Button support (#708) for resetting to factory defaults and other actions
  • new console set command in system, set board_profile <profile> for quickly enabling cabled ethernet connections without using the captive wifi portal
  • added in MQTT nested mode, for thermostat and mixer, like we had back in v2
  • cascade MC400 (product-id 210) (3.0.0b6), power values for heating sources (3.0.1b1)
  • values for wwMaxPower, wwFlowtempOffset
  • RC300 thermostat temp -1 to clear temporary setpoint in auto mode
  • syslog port selectable (#744)
  • individual mqtt commands (#31)
  • board Profiles (#11)

Fixed

  • telegrams matched to masterthermostat 0x18
  • multiple roomcontrollers
  • readback after write with delay (give ems-devices time to set the value)
  • thermostat ES72/RC20 device 66 to command-set RC20_2
  • MQTT payloads not adding to queue when MQTT is re-connecting (fixes #369)
  • fix for HA topics with invalid command formats (#728)
  • wrong position of values #723, #732
  • OTA Upload via Web on OSX
  • Rx and Tx quality % would sometimes show > 100

Changed

  • changed how telegram parameters are rendered for mqtt, console and web (#632)
  • split show values in smaller packages (edited)
  • extended length of IP/hostname from 32 to 48 chars (#676)
  • check flowsensor for tap_water_active
  • mqtt prefixed with Base
  • count Dallas sensor fails
  • switch from SPIFFS to LITTLEFS
  • added ID to MQTT payloads which is the Device's product ID and used in HA to identify a unique HA device
  • increased MQTT buffer and reduced wait time between publishes
  • updated to the latest ArduinoJson library
  • some names of mqtt-tags like in v2.2.1
  • new ESP32 partition side to allow for smoother OTA and fallback
  • network Gateway IP is optional (#682)emsesp/EMS-ESP
  • moved to a new GitHub repo https://github.com/emsesp/EMS-ESP32
  • invert LED changed to Hide LED. Default is off.
  • renamed Scan Network to Scan WiFi Network
  • added version to cmd=settings
  • Allow both WiFi and Ethernet together, fall back to AP when Ethernet disconnects

Removed

  • Shower Alert (disabled for now)

[3.0.0] March 18 2021

Added

  • Power settings, disabling BLE and turning off Wifi sleep
  • Rx and Tx counts to Heartbeat MQTT payload
  • Ethernet support
  • id to info command to show only a heatingcircuit
  • add sending devices that are not listed to 0x07
  • extra MQTT boolean option for "ON" and "OFF"
  • Support for chunked MQTT payloads to allow large data sets > 2kb
  • External Button support (#708) for resetting to factory defaults and other actions
  • new console set command in system, set ethernet <profile> for quickly enabling cabled ethernet connections without using the captive wifi portal
  • Added in MQTT nested mode, for thermostat and mixer, like we had back in v2
  • Cascade MC400 (product-id 210) (3.0.0b6)
  • values for wwMaxPower, wwFlowtempOffset
  • RC300 thermostat temp -1 to clear temporary setpoint in auto mode
  • Syslog port selectable (#744)

Fixed

  • telegrams matched to masterthermostat 0x18
  • multiple roomcontrollers
  • readback after write with delay (give ems-devices time to set the value)
  • Thermostat ES72/RC20 device 66 to command-set RC20_2
  • MQTT payloads not adding to queue when MQTT is re-connecting (fixes #369)
  • fix for HA topics with invalid command formats (#728)
  • wrong position of values #723, #732
  • OTA Upload via Web on OSX

Changed

  • changed how telegram parameters are rendered for mqtt, console and web (#632)
  • split show values in smaller packages (edited)
  • extended length of IP/hostname from 32 to 48 chars (#676)
  • check flowsensor for tap_water_active
  • mqtt prefixed with Base
  • count Dallas sensor fails
  • switch from SPIFFS to LITTLEFS
  • Added ID to MQTT payloads which is the Device's product ID and used in HA to identify a unique HA device
  • Increased MQTT buffer and reduced wait time between publishes
  • Updated to the latest ArduinoJson library
  • some names of mqtt-tags like in v2.2.1
  • new ESP32 partition side to allow for smoother OTA and fallback
  • Network Gateway IP is optional (#682)emsesp/EMS-ESP
  • moved to a new GitHub repo https://github.com/emsesp/EMS-ESP32