BMS temperature = 0.0 AC3 #303

Open
LeeFarm11 opened this issue Nov 12, 2024 · 7 comments
Open

BMS temperature = 0.0 AC3 #303

LeeFarm11 opened this issue Nov 12, 2024 · 7 comments

Comments

@LeeFarm11
Copy link

Hi. In section GivTCP Battery Stack 1 I have BMS temperature showing 0.0 degrees C.

Dev3.0.39

image

image

@britkat1980
Copy link
Owner

What value does the Portal show? It might be that the 3PH uses a different value for the overall Battery (BMS) temp

@LeeFarm11
Copy link
Author

I don't see any Battery temperatures anywhere. Where should I be looking?
No temperatures in any of these tabs. Here is the battery data.

image

@britkat1980
Copy link
Owner

Not sure, perhaps it doesn’t report it. I can make GivTCP use an average of the cell temps as a proxy?

@LeeFarm11
Copy link
Author

Yes, makes sense. One less spurious reading....

@britkat1980
Copy link
Owner

I've changed BMS_Temperature to be average of cell temps

@IWR69
Copy link

IWR69 commented Nov 24, 2024

I'm still running 2.4.9 but BMS temp is often very different to cell temp, it's much higher when charging and discharging for example, so imo I don't think average cell temp would be good for BMS temp.

Also with 2.4.9 BMS temp often freezes value when charging or discharging. Restarting GivTCP fixes it or it often fixes itself, with the frozen value being replaced with the missing data, sometime after the charge / discharge has completed. Has this been fixed in V3?

@britkat1980
Copy link
Owner

I'm still running 2.4.9 but BMS temp is often very different to cell temp, it's much higher when charging and discharging for example, so imo I don't think average cell temp would be good for BMS temp.

Also with 2.4.9 BMS temp often freezes value when charging or discharging. Restarting GivTCP fixes it or it often fixes itself, with the frozen value being replaced with the missing data, sometime after the charge / discharge has completed. Has this been fixed in V3?

The above refers to Three Phase inverter, which doesn’t have a BMS temp available.