You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Cells 13 - 24 on one of my batteries showing 0. Is this a problem with one of my batteries? Or a problem with REST/GivTCP? Or neither? Or both?
temperatures in cells 13 - 24 not being reported.
In REST output in the "raw" section, I noticed that one of my 6 batteries is showing temperature 0 on cells 13 - 24. The other batteries are showing normal temperatures in cells 13 - 24. t_cell_13 through t_cell_24.
Then I realised that Home Assistant only shows temperatures of cells 1 -12. But shows voltage of cells 1 - 24.
Hi.
There are a couple of potential issues here.
In REST output in the "raw" section, I noticed that one of my 6 batteries is showing temperature 0 on cells 13 - 24. The other batteries are showing normal temperatures in cells 13 - 24. t_cell_13 through t_cell_24.
Then I realised that Home Assistant only shows temperatures of cells 1 -12. But shows voltage of cells 1 - 24.
Full REST output file here -
1.txt
RAW data shows temperatures in all batteries in all cells 1-24 except in one battery showing 0 for 13 - 24. -
Battery Details section does not show any temperatures in any cell 13 - 24 in any battery -
Home screen agrees with REST Battery details section. It shows voltages for cells 1 -24, but temperatures for only cells 1 - 12.
The text was updated successfully, but these errors were encountered: