A big confusion/complaint we recieve, not just about how the indicator is a property of the ImagingPlane (this is currently fixed in ndx-microscopy design) but also how the emission_lambda is (a) not a scalar and (b) a spectrum known from the indicator
Instead, it seems that the intention of this value is to represent the 'median wavelength selected by the optical filter'; I've also needed or wanted to attach bounds on that filtering as indicated by the methods section of multiple papers
As such I'd propose changing the name to something like filter_wavelength_median and also add filter_wavelength_range (or @alessandratrapani preferred 'bandwidth') which is a [2] (float) with both properties in units of nanometers
The text was updated successfully, but these errors were encountered:
CodyCBakerPhD
changed the title
Change name of emission wavelength ob the OpticalChannel
Change name of emission wavelength on the OpticalChannel
Dec 18, 2023
A big confusion/complaint we recieve, not just about how the
indicator
is a property of theImagingPlane
(this is currently fixed inndx-microscopy
design) but also how theemission_lambda
is (a) not a scalar and (b) a spectrum known from the indicatorInstead, it seems that the intention of this value is to represent the 'median wavelength selected by the optical filter'; I've also needed or wanted to attach bounds on that filtering as indicated by the methods section of multiple papers
As such I'd propose changing the name to something like
filter_wavelength_median
and also addfilter_wavelength_range
(or @alessandratrapani preferred 'bandwidth') which is a[2] (float)
with both properties inunits
ofnanometers