[hardware::server::cisco::ucs::snmp::plugin] uninitialized values #4995
Comments
Hello, We've been searching for over a year on how to read the temperature and power via SNMP from a CISCO UCSX-210C-M6 blade. They also provided this link with additional information. I noticed that the status of the blade (power on/off) doesn't use the same OID (OperPower/OperStatus) as the one used in your script. Could you do something with the corresponding OID .1.3.6.1.4.1.9.9.719.1.9 (and below) to adjust your script to the latest OIDs? And perhaps you could also provide the temperature (front/rear) and POWER as performance data!? regards, |
snmpwalk for OID .1.3.6.1.4.1.9.9.719.1.9 (cucsComputeObjects)
|
Hello :) If I understand correctly, the plugin no longer works on blade components beyond version 5.1? And you would also have the temperature to be added for versions > 5.1? Anyway, to be able to adapt the plugin to this new equipment (>5.1) we would need the MIBs (specifically those associated with your equipment) and also if you can you provide us an SNMPWalk with OIDs number rather than label ? Like this : |
Hello, see here the snmpwalk but with numbers : snmpwalk x.x.x.x 1.3.6.1.4.1.9.9.719.1.9.2 .1.3.6.1.4.1.9.9.719.1.9.2.1.2.1 = STRING: "sys/chassis-1/blade-1/blade" |
blade oper -> ".1.3.6.1.4.1.9.9.719.1.9.2.1.40.1" |
For blades on USCX, it is only possible to perform monitoring via SNMP for Status/Temp/Power from version 5.2 onwards. The OIDs you are currently using are think for UCS-C but not for the USC-X (firmware 5.2) |
Hello :) Thank you very much for all these very clear details :) |
Hello, I have reviewed the emails with CISCO once more and found this as a link. So if I see it correctly, the temp/power... is available from version 5.1.0 (in the emails they mentioned from version 5.2). If I am correct, then it is basically a matter of checking if the OID cucsAdaptorUnitTable exists, and then you know that the temp/power/... option is available (Firmware 5.1.0 or higher). I see this in the web page :
We only have UCSX equipment, so it is difficult to compare with other CISCO hardware. When I look at this link, I get the impression that version 5.2 is not yet available for the UCS-C. Regarding the UCSX, I think you can only see this in the description of the blade.
|
Hello :) Thank you for all these elements, I was able to complete the necessary fields to propose an enhancement of the plugin. Let me close this issue here because it is now an enhancement request and these are managed on TheWatch Ideas to be vote on (you can create a new idea and link this github issue in your proposition). |
Hello,
Bug report
I have multiple variables that are not initialized in the output
How to reproduce
Here are the error messages that I'm getting
centreon_plugins.pl' '--filter-uom' '(none)' '--hostname' 'x.x.x.x' '--plugin' 'hardware::server::cisco::ucs::snmp::plugin' '--snmp-autoreduce' '2' '--snmp-community' 'public' '--snmp-version' '2' '--mode' 'equipment' --debug --verbose
Please provide below the initial conditions to reproduce the bug
Cisco UCSX-210C-M6 - Firmware Version 5.2(0.230040)
regards,
Geert