-
Notifications
You must be signed in to change notification settings - Fork 2
/
create_container.sh
180 lines (161 loc) · 5.39 KB
/
create_container.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
#!/usr/bin/env bash
# Setup script environment
set -o errexit #Exit immediately if a pipeline returns a non-zero status
set -o errtrace #Trap ERR from shell functions, command substitutions, and commands from subshell
set -o nounset #Treat unset variables as an error
set -o pipefail #Pipe will exit with last non-zero status if applicable
shopt -s expand_aliases
alias die='EXIT=$? LINE=$LINENO error_exit'
trap die ERR
trap cleanup EXIT
function error_exit() {
trap - ERR
local DEFAULT='Unknown failure occured.'
local REASON="\e[97m${1:-$DEFAULT}\e[39m"
local FLAG="\e[91m[ERROR] \e[93m$EXIT@$LINE"
msg "$FLAG $REASON"
[ ! -z ${CTID-} ] && cleanup_ctid
exit $EXIT
}
function warn() {
local REASON="\e[97m$1\e[39m"
local FLAG="\e[93m[WARNING]\e[39m"
msg "$FLAG $REASON"
}
function info() {
local REASON="$1"
local FLAG="\e[36m[INFO]\e[39m"
msg "$FLAG $REASON"
}
function msg() {
local TEXT="$1"
echo -e "$TEXT"
}
function cleanup_ctid() {
if [ ! -z ${MOUNT+x} ]; then
pct unmount $CTID
fi
if $(pct status $CTID &>/dev/null); then
if [ "$(pct status $CTID | awk '{print $2}')" == "running" ]; then
pct stop $CTID
fi
pct destroy $CTID
elif [ "$(pvesm list $STORAGE --vmid $CTID)" != "" ]; then
pvesm free $ROOTFS
fi
}
function cleanup() {
popd >/dev/null
rm -rf $TEMP_DIR
}
function load_module() {
if ! $(lsmod | grep -Fq $1); then
modprobe $1 &>/dev/null || \
die "Failed to load '$1' module."
fi
MODULES_PATH=/etc/modules
if ! $(grep -Fxq "$1" $MODULES_PATH); then
echo "$1" >> $MODULES_PATH || \
die "Failed to add '$1' module to load at boot."
fi
}
TEMP_DIR=$(mktemp -d)
pushd $TEMP_DIR >/dev/null
# Download setup script
wget -qL https://github.com/chpego/proxmox_unifi_network_controler_lxc/raw/main/setup.sh
# Detect modules and automatically load at boot
load_module aufs
load_module overlay
# Select storage location
while read -r line; do
TAG=$(echo $line | awk '{print $1}')
TYPE=$(echo $line | awk '{printf "%-10s", $2}')
FREE=$(echo $line | numfmt --field 4-6 --from-unit=K --to=iec --format %.2f | awk '{printf( "%9sB", $6)}')
ITEM=" Type: $TYPE Free: $FREE "
OFFSET=2
if [[ $((${#ITEM} + $OFFSET)) -gt ${MSG_MAX_LENGTH:-} ]]; then
MSG_MAX_LENGTH=$((${#ITEM} + $OFFSET))
fi
STORAGE_MENU+=( "$TAG" "$ITEM" "OFF" )
done < <(pvesm status -content rootdir | awk 'NR>1')
if [ $((${#STORAGE_MENU[@]}/3)) -eq 0 ]; then
warn "'Container' needs to be selected for at least one storage location."
die "Unable to detect valid storage location."
elif [ $((${#STORAGE_MENU[@]}/3)) -eq 1 ]; then
STORAGE=${STORAGE_MENU[0]}
else
while [ -z "${STORAGE:+x}" ]; do
STORAGE=$(whiptail --title "Storage Pools" --radiolist \
"Which storage pool you would like to use for the container?\n\n" \
16 $(($MSG_MAX_LENGTH + 23)) 6 \
"${STORAGE_MENU[@]}" 3>&1 1>&2 2>&3) || exit
done
fi
info "Using '$STORAGE' for storage location."
# Get the next guest VM/LXC ID
CTID=$(pvesh get /cluster/nextid)
info "Container ID is $CTID."
# Download latest Debian 10 LXC template
msg "Updating LXC template list..."
pveam update >/dev/null
msg "Downloading LXC template..."
OSTYPE=debian
OSVERSION=${OSTYPE}-10
mapfile -t TEMPLATES < <(pveam available -section system | sed -n "s/.*\($OSVERSION.*\)/\1/p" | sort -t - -k 2 -V)
TEMPLATE="${TEMPLATES[-1]}"
pveam download local $TEMPLATE >/dev/null ||
die "A problem occured while downloading the LXC template."
# Create variables for container disk
STORAGE_TYPE=$(pvesm status -storage $STORAGE | awk 'NR>1 {print $2}')
case $STORAGE_TYPE in
dir|nfs)
DISK_EXT=".raw"
DISK_REF="$CTID/"
;;
zfspool)
DISK_PREFIX="subvol"
DISK_FORMAT="subvol"
;;
esac
DISK=${DISK_PREFIX:-vm}-${CTID}-disk-0${DISK_EXT-}
ROOTFS=${STORAGE}:${DISK_REF-}${DISK}
# Create variables for container memory
# https://help.ui.com/hc/en-us/articles/360012282453-UniFi-Set-up-a-UniFi-Network-Controller#h_01EKX52R32QMPRJMXXYWSWJF7W
MEMORY=2048
SWAP_MEMORY=$MEMORY
# Create LXC
msg "Creating LXC container..."
DISK_SIZE=20G
pvesm alloc $STORAGE $CTID $DISK $DISK_SIZE --format ${DISK_FORMAT:-raw} >/dev/null
if [ "$STORAGE_TYPE" == "zfspool" ]; then
warn "Some containers may not work properly due to ZFS not supporting 'fallocate'."
else
mkfs.ext4 $(pvesm path $ROOTFS) &>/dev/null
fi
ARCH=$(dpkg --print-architecture)
#-----replace HOSTNAME here----
HOSTNAME=UnifiNetworkController
TEMPLATE_STRING="local:vztmpl/${TEMPLATE}"
pct create $CTID $TEMPLATE_STRING -arch $ARCH -features nesting=1 \
-hostname $HOSTNAME -net0 name=eth0,bridge=vmbr0,ip=dhcp -onboot 1 \
-ostype $OSTYPE -rootfs $ROOTFS,size=$DISK_SIZE -swap $SWAP_MEMORY -memory $MEMORY -storage $STORAGE >/dev/null
# Set container timezone to match host
MOUNT=$(pct mount $CTID | cut -d"'" -f 2)
ln -fs $(readlink /etc/localtime) ${MOUNT}/etc/localtime
pct unmount $CTID && unset MOUNT
# Setup container
msg "Starting LXC container..."
pct start $CTID
pct push $CTID setup.sh /setup.sh -perms 755
pct exec $CTID /setup.sh
# Get network details and show completion message
IP=$(pct exec $CTID ip a s dev eth0 | sed -n '/inet / s/\// /p' | awk '{print $2}')
info "Successfully created Unifi Network Controller LXC to $CTID."
msg "
WebInterface is reachable by going to the following URLs.
https://${IP}:8443
https://${HOSTNAME}:8443
"
# Set container description
pct set $CTID -description "Access web interface using the following URL.
https://${IP}:8443"