Notifications
You must be signed in to change notification settings - Fork 0
/
EnableBDE.ps1
36 lines (29 loc) · 1.76 KB
/
EnableBDE.ps1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
# Get the target volume's encryption properties.
$volume = Get-WmiObject win32_EncryptableVolume `
-Namespace root\CIMv2\Security\MicrosoftVolumeEncryption `
-Filter "DriveLetter = 'C:'"
# Get the target system's manufacturer.
$manufacturer = (get-wmiobject win32_computersystem).Manufacturer
#set BIOS password and create output
set-location \\s-server.dccmpy.com\Share$\EnableBDE\DellApp; .\cctk.exe --setuppwd=biospassword | Out-File -Append \\s-server.dccmpy.com\Share$\EnableBDE\$env:computername.txt
#remove BIOS password
#set-location \\s-server.dccmpy.com\Share$\EnableBDE\DellApp; .\cctk.exe --setuppwd= --valsetuppwd=Rfb10s
# If the manufacturer is Dell, and the volume is not encrypted, prepare it.
if ( $manufacturer -eq "Dell Inc." -and ( $volume.encryptionmethod -eq 0 -or !$volume) ) {
$tpm = get-TPM
}
# Is the TPM not enabled? Enable it.
if ( $tpm.TpmReady -eq $false ) {
set-location \\s-server.dccmpy.com\Share$\EnableBDE\DellApp; .\cctk.exe --tpm=on --valsetuppwd=biospassword | Out-File -Append \\s-server.dccmpy.com\Share$\EnableBDE\TPMOn\$env:computername.txt
set-location \\s-server.dccmpy.com\Share$\EnableBDE\DellApp; .\cctk.exe --tpmactivation=activate --valsetuppwd=biospassword | Out-File -Append \\s-server.dccmpy.com\Share$\EnableBDE\TPMActive\$env:computername.txt
}
# Get the target Computer Name.
$name = (get-wmiobject win32_computersystem).Name
# Is there not an encryptable volume? Make C: encryptable with bdehdcfg.
if ( -not $volume ) {
bdehdcfg -target default -quiet
}
# If this is a Dell machine that is not encrypted, encrypt it.
if ( $manufacturer -eq "Dell Inc." -and $volume.encryptionmethod -eq 0 ) {
manage-bde -on c: -s -rp -used | Out-File -Append set-location \\s-server.dccmpy.com\Share$\EnableBDE\$env:computername.txt
}