Notifications
You must be signed in to change notification settings - Fork 92
HydraFW binary 1 Wire mode guide
Baldanos edited this page Nov 7, 2016
·
10 revisions
#HydraFW binary 1-Wire mode guide
This guide is updated towards development firmware
##Commands Once the raw-wire mode has been selected, the following commands are available :
-
0b00000000
Return to main mode. ReturnsBBIO1
-
0b00000010
Bus reset -
0b00000100
Read byte -
0b0001xxxx
Bulk raw-wire transfer
##Command details
###Bus reset (0b00000010
)
This command sends a bus reset signal on the 1-Wire bus. No value is sent back.
###Read byte (0b00000100
)
This command reads a byte on the 1-Wire bus, and sends it back to the user.
###Bulk 1-Wire transfer (0b0001xxxx
)
In this mode, the last 4 bits of the command define the number of bytes to write (from 1 to 16) (Command 0b00010000
will send 1 byte). Hydrabus will wait for the defined number of bytes, then send a 0x01
(acknowledge).
- CHANGELOG
- Console commands
- Binary mode guide
-
NFC/HydraNFC v1 guide
- Read UID of an ISO/IEC_14443 Tag
- Read UID and data of a MIFARE Ultralight Tag
- Read UID of an ISO/IEC 15693 Tag
- Emul ISO14443a Tag
- Emul MIFARE Ultralight Tag
- Emul Mifare Classic Tag
- Unique NFC sniffer design
- Launch NFC sniffer from console
- Sniffer ISO14443A wireshark pcap
- Autonomous/stand-alone sniffer mode
- Sniffer ISO14443A real-time infinite trace mode
- HydraFW-HydraNFC-v1.x-TRF7970A-Tutorial