diff --git a/doc/nrf/known_issues.rst b/doc/nrf/known_issues.rst index b828d652a760..54dc91fe234a 100644 --- a/doc/nrf/known_issues.rst +++ b/doc/nrf/known_issues.rst @@ -1025,6 +1025,95 @@ KRKNWK-8133: CSMA-CA issues SoftDevice Controller ===================== +.. rst-class:: v1-6-0 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 + +DRGN-15852: In rare cases on nRF53 Series devices, an assert can occur while scanning + This only occurs when the host started scanning using HCI LE Set Scan Enable. + This is default configuration of the Bluetooth host. + + **Workaround:** Use extended scanning commands. + That is, set :option:`CONFIG_BT_EXT_ADV` to use HCI LE Set Extended Scan Enable instead. + +.. rst-class:: v1-6-0 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 + +DRGN-15852: In rare cases on nRF53 Series, the scanner generates corrupted advertising reports + The following fields are affected: + + * Event_Type + * Address_Type + * Direct_Address_Type + * TX_Power + * Advertising_SID + +.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15586: "HCI LE Set Scan Parameters" accepts a scan window greater than the scan interval + This can result in undefined behavior. It should fail with the result "Invalid HCI Command Parameters (0x12)". + + **Workaround:** The application should make sure the scan window is set to less than or equal to the scan interval. + +.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 + +DRGN-15547: Assertion when updating PHY and the event length is configured too low + The SoftDevice Controller may assert if: + + * :c:union:`sdc_cfg_t` with :c:member:`event_length` is set to less than 2500 us and the PHY is updated from 2M to 1M, or from either 1M or 2M to Coded PHY. + * :c:union:`sdc_cfg_t` with :c:member:`event_length` is set to less than 7500 us and a PHY update to Coded PHY is performed. + + | The default value of :option:`CONFIG_SDC_MAX_CONN_EVENT_LEN_DEFAULT` is 7500 us. + | The minimum event length supported by :option:`CONFIG_SDC_MAX_CONN_EVENT_LEN_DEFAULT` is 2500 us. + + **Workaround:** + * Set :c:union:`sdc_cfg_t` with :c:member:`event_length` to at least 2500 us if the application is using 1M PHY. + * Set :c:union:`sdc_cfg_t` with :c:member:`event_length` to at least 7500 us if the application is using Coded PHY. + +.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-13594: The channel map provided by the LE Host Set Channel Classification HCI command is not always applied on the secondary advertising channels + In this case, the extended advertiser can send secondary advertising packets on channels which are disabled by the Host. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15338: Extended scanner may generate reports containing truncated data from chained advertising PDUs + The scanner reports partial data from advertising PDUs when there is not enough storage space for the full report. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15469: Slave connections can disconnect prematurely if there are scheduling conflicts with other roles + This is more likely to occur during long-running events such as flash operations. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 + +DRGN-15369: Radio output power cannot be set using the vendor-specific HCI command Zephyr Write TX Power Level for all power levels + The command returns "Unsupported Feature or Parameter value (0x11)" if the chosen power level is not supported by the used hardware platform. + + **Workaround** Only select output power levels that are supported by the hardware platform. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15694: An assert can occur when running an extended advertiser with maximum data length and minimum interval on Coded PHY + The assert only occurs if there are scheduling conflicts. + + **Workaround** Ensure the advertising interval is configured to at least 30 milliseconds when advertising on LE Coded PHY. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15484: A connectable or scannable advertiser may end with sending a packet without listening for the ``CONNECT_IND``, ``AUX_CONNECT_REQ``, ``SCAN_REQ``, or ``AUX_SCAN_REQ`` + These packets sent by the scanner or initiator can end up ignored in some cases. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15531: The coding scheme provided by the LE Set PHY HCI Command is ignored after a remote initiated PHY procedure + The PHY options set by the host in LE Set PHY command are reverted when the remote initiates a PHY update. + This happens because of the automatic reply of a PHY update Request in the SoftDevice Controller. + This makes it impossible to change the PHY preferred coding in both directions. + When receiving on S2, the SoftDevice Controller will always transmit on S8 even when configured to prefer S2. + +.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15758: The controller may still have pending events after :c:func:`sdc_hci_evt_get()` returns false + This will only occur if the host has masked out events. + .. rst-class:: v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 DRGN-15251: Very rare assertion fault when connected as peripheral on Coded PHY @@ -1068,6 +1157,17 @@ DRGN-15382: The SoftDevice Controller cannot be qualified on nRF52832 **Workaround:** Upgrade to v1.5.1 or use the master branch. +.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-14008: The advertising data is cleared every time the advertising set is configured + This causes the "HCI LE Set Extended Advertising Parameters" command to accept data which cannot be fit within the advertising interval instead of returning "Packet Too Long (0x45)". + This would only occur if the advertising set is configured to use maximum data length on LE Coded PHY with an advertising interval less than 30 milliseconds. + +.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-15291: The generation of QoS Connection events is not disabled after an HCI reset + Some event reports may still occur after a reset. + .. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 DRGN-15226: Link disconnects with reason "LMP Response Timeout (0x22)" @@ -1094,6 +1194,33 @@ DRGN-13921: Directed advertising issues using RPA in TargetA DRGN-10367: Advertiser times out earlier than expected If an extended advertiser is configured with limited duration, it will time out after the first primary channel packet in the last advertising event. +.. rst-class:: v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 + +DRGN-11222: A Central may disconnect prematurely if there are scheduling conflicts while doing a control procedure with an instant + This bug will only be triggered in extremely rare cases. + +.. rst-class:: v1-1-0 v1-0-0 + +DRGN-13231: A control packet may be sent twice even after the packet is ACKed + This only occurs if the radio is forced off due to an unforeseen condition. + +.. rst-class:: v1-1-0 v1-0-0 + +DRGN-13350: HCI LE Set Extended Scan Enable returns "Unsupported Feature or Parameter value (0x11)" + This occurs when duplicate filtering is enabled. + + **Workaround** Do not enable duplicate filtering in the controller. + +.. rst-class:: v1-1-0 v1-0-0 + +DRGN-12122: ``secondary_max_skip`` cannot be set to a non-zero value + HCI LE Set Advertising Parameters will return "Unsupported Feature or Parameter value (0x11)" when ``secondary_max_skip`` is set to a non-zero value. + +.. rst-class:: v1-1-0 v1-0-0 + +DRGN-13079: An assert occurs when setting a secondary PHY to 0 when using HCI LE Set Extended Advertising Parameters + This issue occurs when the advertising type is set to legacy advertising. + .. rst-class:: v1-1-0 :option:`CONFIG_BT_HCI_TX_STACK_SIZE` requires specific value @@ -1127,10 +1254,10 @@ Sending control packet twice A control packet could be sent twice even after the packet was acknowledged. This would only occur if the radio was forced off due to an unforeseen condition. -.. rst-class:: v1-1-0 v1-0-0 +.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0 -Wait time required after a directed high duty cycle advertiser times out - The application is unable to restart a connectable advertiser right after a high-duty-cycle advertiser times out. +DRGN-13029: The application will not immediately restart a connectable advertiser after a high duty cycle advertiser times out + In some cases, the host may restart advertising sooner than the SoftDevice Controller is able to free its connection context. **Workaround:** Wait 500 ms before restarting a connectable advertiser @@ -1139,21 +1266,6 @@ Wait time required after a directed high duty cycle advertiser times out Assert risk after performing a DLE procedure The controller could assert when receiving a packet with a CRC error on LE Coded PHY after performing a DLE procedure where RX Octets is changed to a value above 140. -.. rst-class:: v1-1-0 v1-0-0 - -Assert when using HCI LE Set Extended Advertising Parameters - The controller will assert when setting secondary PHY to 0 when using HCI LE Set Extended Advertising Parameters and the advertising type is set to legacy advertising. - -.. rst-class:: v1-1-0 v1-0-0 - -HCI issues with duplicate filtering - HCI LE Set Extended Scan Enable returns `UNSUPPORTED_FEATURE` when duplicate filtering is enabled. - -.. rst-class:: v1-1-0 v1-0-0 - -HCI issues with `secondary_max_skip` - HCI LE Set Advertising Parameters returns `UNSUPPORTED_FEATURE` when `secondary_max_skip` is set to a non-zero value. - .. rst-class:: v1-0-0 No data issue when connected to multiple devices