Osazeni hrebinku #1
Comments
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
na GH4PIN01A je treba, aby byly osazeny JSTGH konektory ze stejne strany jako hrebinek, protoze JSTGH konektory maji zamek smerem od PCB
kdyby byla deska JSTGH konektory smerem k ALBASE, nesly by konektory bez nastroje vypojit
ma to trochu problem, ze potisk s popiskama konektoru je z druhe strany