From 155b3716a13d2eb1945c0a6b144e2dd656dbb15f Mon Sep 17 00:00:00 2001 From: woutdenolf Date: Wed, 15 May 2024 14:11:32 +0200 Subject: [PATCH] fix misconception about energy/wavelength --- contributed_definitions/NXstress.nxdl.xml | 20 ++++++-------------- 1 file changed, 6 insertions(+), 14 deletions(-) diff --git a/contributed_definitions/NXstress.nxdl.xml b/contributed_definitions/NXstress.nxdl.xml index 0a4c3fd784..317e117146 100644 --- a/contributed_definitions/NXstress.nxdl.xml +++ b/contributed_definitions/NXstress.nxdl.xml @@ -212,7 +212,6 @@ Date calibration was created/added - @@ -237,18 +236,6 @@ - - - Source energy. The energy should be provided in keV, but if chosen otherwise, the units must be clearly specified. For storage rings, this would be the particle beam energy. - For X-ray tubes, this would be the excitation voltage. - - - - - - In case of monochromatic radiation, the wavelength used during the experiment. The wavelength should be provided in \ :math:`Å`, but if chosen otherwise, the units must be clearly specified. - - Zero or more of these groups describe the detectors used in the experiment. @@ -290,7 +277,6 @@ In this use case, the efficiency and wavelength arrays must have the same dimensionality. - @@ -411,6 +397,12 @@ Describes how the beam intensity profile in the secondary horizontal direction was determined. Examples of valid entries are: ``measured``, ``theoretical``, ``estimated``, ... + + Incident energy mostly useful for monochromatic beams. + + + Incident wavelength mostly useful for monochromatic beams. +