User reports:
When the MiniscopeV4BNO055 node is added to the workflow, you will not be able to click the MiniscopeV4BNO055 node nor MiniscopeV4 node. Otherwise bonsai will crash and data might not be saved.
Error in recv. Chnl: 3, Timeout: 0, GetOverlappedResult: 170
This is temporarily solved by externalizing LEDBrightness and LiquidLensVoltage properties and controlling them via the double node.
After the bonsai crash, the miniscope node will show Failure to read from a stream or register warning and need a PC power off to reset the PCIe host.
This could be due to having used neuropixels headstage in the same port prior (#20).
Suggestion: should the issues arise, the device can be used considering this workaround. The course of action would be migrating to the new library once that has miniscope v4 support.
The text was updated successfully, but these errors were encountered:
Sign up for freeto subscribe to this conversation on GitHub.
Already have an account?
Sign in.
User reports:
When the MiniscopeV4BNO055 node is added to the workflow, you will not be able to click the MiniscopeV4BNO055 node nor MiniscopeV4 node. Otherwise bonsai will crash and data might not be saved.
Error in recv. Chnl: 3, Timeout: 0, GetOverlappedResult: 170
This is temporarily solved by externalizing LEDBrightness and LiquidLensVoltage properties and controlling them via the double node.
After the bonsai crash, the miniscope node will show Failure to read from a stream or register warning and need a PC power off to reset the PCIe host.
This could be due to having used neuropixels headstage in the same port prior (#20).
Suggestion: should the issues arise, the device can be used considering this workaround. The course of action would be migrating to the new library once that has miniscope v4 support.