Cluster 0x80
→ Broadcast 0xbf
The cluster will broadcast the odometer if requested.
0x16
Odometer Request
80 0A BF 17 FA 34 0C 00 1F 32 CC 01
Fixed length. 3 data bytes.
Parameter | Index | Length | Type | Note |
---|---|---|---|---|
Mileage | 0-2 |
3 |
Integer | km |
The mileage consists of 3 bytes. It can be calculated into a readable integer using the following formular:
mileage = (byte3 * 655536) + (byte2 * 256) + byte1
mileage = (0x0C * 65536) + (0x34 * 256) + 0xFA
mileage = (12 * 65536) + (52 * 256) + 250
mileage = 799994
# Example Odometer Frame
80 0A BF 17 FA 34 0C 00 1F 32 CC 01
Property | Mileage |
---|---|
Data | FA 34 0C |
Value | 799994 km |
Increases the mileage in EWS and inserted key