Notifications
You must be signed in to change notification settings - Fork 1
/
ECG_signal_processing.m
144 lines (124 loc) · 5.17 KB
/
ECG_signal_processing.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
% Copyright (c) Prasanth "Prash" Ganesan
% Author email: <prasganesan.pg@gmail.com>
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%---------------------------------------------------
clear
% Add the wfdb-app-toolbox-0-9-10 toolbox to the path
% MIT BIH NSR database
% The database has 18 long-term ECG recordings and are recorded from patients
% from the Arrhythmia Laboratory at Boston's Beth Israel Hospital.
% All patients had normal heart rhythm and the population include 5 men,
% aged 26 to 45, and 13 women, aged 20 to 50.
% Import ecg
[t,ECG]=rdsamp('nsrdb/16265',[1],1000);
ann=rdann('nsrdb/16265','atr',[],1000);
fs=128;
time_req=3; % required time is 3 sec
samples = time_req*fs;
new_time = linspace(0,time_req,samples);
new_ecg=ECG(1:samples);
figure; plot(new_time,new_ecg);
title('3 sec of ECG')
xlabel('Time (sec)')
ylabel('Amplitude')
% Plot annotations over that
hold on;
plot(ann(ann<=samples)./fs,new_ecg(ann(ann<=samples)),'r*');
%%--------------------------------------------
clear
time_req=2*3600; % 2 hours data
fs=128;
samples = time_req*fs;
[t,ECG]=rdsamp('nsrdb/16265',[1],samples);
ECG=ECG(:);
ann=rdann('nsrdb/16265','atr',[],samples);
ann=ann(:,1);
[HR_vec,tot_avg_HR,var_HR] = cal_HR(ECG,ann);
%%-------------------------------------------------------------------
clear
% MIT-BIH AFib database
% Atrial fibrillation is one of the life-threatening arrhythmia that is
% cahracterized by irregular and fast beating of the atria. It is caused by
% disorganization of the signals in the atria surface. The MIT-BIH afib
% database includes 25 long-term recordings of mostly paroxysmal afib
% patients. They are 10 hours ECG signal sampled at 250 samples/sec. The
% recordings were obtained from Boston's Beth Israel Hospital with the
% operating bandwidth of ECG monitors to be 0.1 to 40 Hz. The amplitude
% range of the recordings are -10 to +10 millivolts.
% Import and Plot signal
[t,ECG]=rdsamp('afdb/04015',[1],1000);
fs=250;
time_req=3; % required time is 3 sec
samples = time_req*fs;
new_time = linspace(0,time_req,samples);
new_ecg=ECG(1:samples);
figure; plot(new_time,new_ecg);
title('3 sec of Atrial Fibrillation ECG')
xlabel('Time (sec)')
ylabel('Amplitude')
% Disease description
% The disease present in the signal is atrial fibrillation. It can be
% clearly seen that the signals are morphologically inconsistent with no
% p-wave present. Although the R waves are not noisy, the time intervals
% of R-waves are completely irregular and the
% baseline is fractionated.
%%---------------------------------------------------
clear
% Import and Plot signal
[t,ECG1]=rdsamp('ecgiddb/Person_01/rec_5',[1],4000);
figure; plot(t,ECG1);
title('Time domain of ECG-ID database signal')
xlabel('Time (sec)')
ylabel('Amplitude')
% Plot in Frequency domain
N_fft= length(ECG1);
L = length(ECG1);
fs = 500;
ECG1_fft = abs(fft(ECG1));
f = [0:(N_fft-1)]*fs/L;
figure; plot(f,abs(ECG1_fft))
xlabel('frequency (Hz)'); title('Frequqncy domain of ECG')
% Design the high pass filter
% From the frequency domain plot, we can see that the noise is present at
% around 1 to 2 Hz (see the high amplitude at the beginning). Se we need to
% pass from 10 Hz and stop till 5 Hz. The amplitude is also chosen till
% 150.
Fstop = 5; % Stopband Frequency
Fpass = 10; % Passband Frequency
Astop = 150; % Stopband Attenuation (dB)
Apass = 0.01; % Passband Ripple (dB)
Fs = 500; % Sampling Frequency
h = fdesign.highpass('fst,fp,ast,ap', Fstop, Fpass, Astop, Apass, Fs);
IIR_HPF = design(h, 'ellip', 'SystemObject', true);
% Design low pass filter
% From the frequency domain plot we can see that the noise is present at 50
% Hz. Hence we need to choose the stop band to include 50 Hz.
Fpass = 45; % Passband Frequency
Fstop = 55; % Stopband Frequency
Apass = 0.01; % Passband Ripple (dB)
Astop = 150; % Stopband Attenuation (dB)
Fs = 500; % Sampling Frequency
h = fdesign.lowpass('fp,fst,ap,ast', Fpass, Fstop, Apass, Astop, Fs);
IIR_LPF = design(h, 'ellip', 'SystemObject', true);
% View the filters
fvtool(IIR_HPF,'Fs',Fs); title('IIR HPF frequency response')
[b_HPF,a_HPF]=sos2tf(IIR_HPF.SOSMatrix,IIR_HPF.ScaleValues);
fvtool(IIR_LPF,'Fs',Fs); title('IIR LPF frequency response')
[b_LPF,a_LPF]=sos2tf(IIR_LPF.SOSMatrix,IIR_LPF.ScaleValues);
% Filtered signal
y_IIR_HPF = filter(b_HPF,a_HPF,ECG1);
figure; plot(t,ECG1); hold on; plot(t,y_IIR_HPF);
xlabel('time(sec)'); title('IIR HPF filtered response (Baseline wander has been removed)')
legend({'Original signal','Baseline wander Filtered Signal'});
y_IIR_HPF_LPF = filter(b_LPF,a_LPF,y_IIR_HPF);
figure; plot(t,ECG1); hold on; plot(t,y_IIR_HPF_LPF);
xlabel('time(sec)'); title('IIR HPF+LPF filtered response (Baseline wander + powerline noise both has been removed)')
legend({'Original signal','Baseline wander + Powerline noise Filtered Signal'});
% Frequency Domain of filtered signal
y_fft = abs(fft(y_IIR_HPF_LPF));
N_FFT = length(y_fft);
L = length(y_fft);
f = [0:(N_FFT-1)]*Fs/L;
figure; plot(f,y_fft);
xlabel('frequency (Hz)');
title('FFT of the designed Filter Response')