{"payload":{"feedbackUrl":"https://github.com/orgs/community/discussions/53140","repo":{"id":591994402,"defaultBranch":"main","name":"StiebelEltron-heatpump-over-esphome-can-bus","ownerLogin":"roberreiter","currentUserCanPush":false,"isFork":false,"isEmpty":false,"createdAt":"2023-01-22T15:51:20.000Z","ownerAvatar":"https://avatars.githubusercontent.com/u/58906113?v=4","public":true,"private":false,"isOrgOwned":false},"refInfo":{"name":"","listCacheKey":"v0:1674402680.77541","currentOid":""},"activityList":{"items":[{"before":"6318247bb4c6c156149054a9cc224a0ea5dc0808","after":"7961272a20dcaba5d018afd6e047764607462c3a","ref":"refs/heads/main","pushedAt":"2023-08-04T19:12:13.000Z","pushType":"push","commitsCount":1,"pusher":{"login":"roberreiter","name":null,"path":"/roberreiter","primaryAvatarUrl":"https://avatars.githubusercontent.com/u/58906113?s=80&v=4"},"commit":{"message":"Update README.md\n\nadded some notes to correctly implement all three relevant buttons for transmitting CAN-messages.","shortMessageHtmlLink":"Update README.md"}},{"before":"890bc881df73abb05c2e03c5000bea9bbb28eed3","after":"6318247bb4c6c156149054a9cc224a0ea5dc0808","ref":"refs/heads/main","pushedAt":"2023-03-11T20:42:55.936Z","pushType":"push","commitsCount":1,"pusher":{"login":"roberreiter","name":null,"path":"/roberreiter","primaryAvatarUrl":"https://avatars.githubusercontent.com/u/58906113?s=80&v=4"},"commit":{"message":"automations.yaml\n\nAs I was asked to, I hereby share one of my automations to set the water temperature depending on the photovoltaic power showed on my fronius smart meter.\r\nIt may not be perfect, but works quite well so far.\r\n\r\nI have two electrical towel radiators in my two bathrooms, consuming around 650 Watt each.\r\nThe power of each radiator can be measured using my two \"sensors sensor.badheizkorper_2_og_leistung_w\" and \"sensor.badheizkorper_wirkleistung_w\"\r\nMy heatpump consumes around 2200 W when it is heating water.\r\nIf I generate more photovoltaic power than consumed at the moment, then the sensor \"sensor.power_real_fronius_meter_0_192_168_1_16\" has a negative value.\r\nIf there is enough power available to make warm water, I increase the comfort-temperature for warm water.\r\nIf there is still enough power, I turn on my electrical radiators every 30 minutes, which are turned off if the available power is lowered.\r\n\r\nI observe the estimated peak time of my photovoltaic modules using \"sensor.power_highest_peak_time_today\"\r\nTomorrow's estimated peak time is given in \"sensor.energy_production_tomorrow\".\r\nIf today's estimated peak time is reached and is 1.7 times higher than tomorrow's estimated peak (meaning not much photovoltaic power tomorrow) I keep the comfort temperature still a bit higher, even if the heatpump consumes slightly more power than available.\r\n(This is still experimental, but sometimes not that bad chosen)\r\n\r\nIf there is not enough power available for some time I reduce the comfort-temperature.\r\n\r\nAnd when the daylight-sensor \"sensor.wt_dammerung_lx\" shows, that there is no more sun available, I set the comfort-temperature to 38°C","shortMessageHtmlLink":"automations.yaml"}}],"hasNextPage":false,"hasPreviousPage":false,"activityType":"all","actor":null,"timePeriod":"all","sort":"DESC","perPage":30,"cursor":"Y3Vyc29yOnYyOpK7MjAyMy0wOC0wNFQxOToxMjoxMy4wMDAwMDBazwAAAANkQM6h","startCursor":"Y3Vyc29yOnYyOpK7MjAyMy0wOC0wNFQxOToxMjoxMy4wMDAwMDBazwAAAANkQM6h","endCursor":"Y3Vyc29yOnYyOpK7MjAyMy0wMy0xMVQyMDo0Mjo1NS45MzYwNTVazwAAAAMBaJ-3"}},"title":"Activity · roberreiter/StiebelEltron-heatpump-over-esphome-can-bus"}