How do I put the sleep mode, and just make read each X time? #4
Comments
The standby current of the BME680 is rated at 0.29 µA, which is pretty low. Typcially, other component on a breakout board like a regulator consume way more than that. As far as I understand it, it will go into standby by itself after a measurement, and the next communication will wake it up again. For a 1 Hz cycle, the average current is given a 3 µA. |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
How do I force the sleep mode and turning on again? I am using a battery in my project, so for consumption I dont want the BME680 be reading all the time