Notifications
You must be signed in to change notification settings - Fork 1
/
TODObveeg_LSLtriggerRDAEEG_check.m
205 lines (175 loc) · 9.42 KB
/
TODObveeg_LSLtriggerRDAEEG_check.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
% Load EEG, trial logging and XDf data for a quick check for EML1
% synchronisation: absolute time on PC1 will be the master clock (to
% facilitate correspondance to the eyetracker events)
datapath = 'C:\Users\roso8920\Dropbox (Emotive Computing)\EyeMindLink\Data';
sublist = [43];
for s = 1:length(sublist)
pID = ['EML1_',sprintf('%03d',sublist(s))];
% for trigger timing to nto get messed up, we need to disable jitter
% removal on xdf load, otherwise it makes itt a regular stream.
xdf_uncorr = load_xdf(fullfile(datapath, pID, [pID,'.xdf']),'HandleJitterRemoval' , false,'Verbose',true,'HandleClockSynchronization',false);
xdf_corr = load_xdf(fullfile(datapath, pID, [pID,'.xdf']),'HandleJitterRemoval' ,false,'Verbose',true,'HandleClockSynchronization',true);
% detect which stream is the trigger
trig_ix = find(strcmp(cellfun(@(sas) sas.info.name, xdf_uncorr,'uni',false),{'eyeLink_trigger'}));
xdf_trig_pc1 = xdf_corr{trig_ix};
xdf_trig_pc2 = xdf_uncorr{trig_ix};
%% get eeg data start time in absolute time, taken from PC2 clock
% note this value is found in the coresponding .vmrk file, todo write
% code to pull this automatically!
temp = fileread(fullfile(datapath, pID, 'EEG', [pID, '.vmrk']));
eeg_start = regexp(temp, 'Mk1=New Segment,,1,1,0,(?<tst>[0-9]{20})','names').tst;
eeg_start = [eeg_start(1:4) '-' eeg_start(5:6) '-' eeg_start(7:8) ' ' eeg_start(9:10) ':' eeg_start(11:12) ':' eeg_start(13:14) '.' eeg_start(15:end)];
eeg_start_pc2abs = datetime(eeg_start, 'Format','yyyy-MM-dd HH:mm:ss.SSSSSS');
%% get the clock offset from the xdf
% this is offset between boot times not between absolute times.
% there are multiple measurements of the offset = we need to decide how to deal w that!
% - Simplest is to compute mean offsest, use as a constant, then consider finer adjustment later w the residuals
% - clock_offsets are the same in teh corrected and uncorrected files -
% its just part of the XDF header
all_offset_tpc1 = str2double({cell2mat(xdf_trig_pc1.info.clock_offsets.offset).time})';
all_offset_val = str2double({cell2mat(xdf_trig_pc1.info.clock_offsets.offset).value})'; % note this is pc2 time minus pc1
mean_offset = mean(all_offset_val); % in sec
range_offset = range(all_offset_val); % in sec
resid_offset = all_offset_val - mean_offset; % in sec, will use later to fine tune timings
figure(99); clf
scatter(all_offset_tpc1,all_offset_val,'.')
xlabel('time (s since PC2 boot)')
ylabel('offset (boot time PC2 - PC1)')
title([pID ' LSL clock offsets'], 'interpreter','none')
%% get the absolute timestamps from the log file on PC1
% earlier participants (software v3) have different log
if sublist(s) <27
logtrig = readtable(fullfile(datapath,pID,[pID '_Trials.txt']) );
% combine date and time to a datetime obj
logtrig.Var1.Format = 'yyyy-MM-dd HH:mm:ss.SSSSSS';
logtrig.datetime = logtrig.Var1 + logtrig.Var2;
logtrig.Var1.Format = 'yyyy-MM-dd';
logtrig.Properties.VariableNames{7} = 'VAL';
else
logtrig = readtable(fullfile(datapath,pID,[pID '_Trials.txt']) ,'Delimiter','\t');
logtrig.Properties.VariableNames{3} = 'VAL';
logtrig.Properties.VariableNames{2} = 'MSG';
% split the first column again by space delimiter
cols = split(logtrig.Var1);
logtrig.datetime =datetime(join( cols(:,1:2),' '));
logtrig.datetime.Format = 'yyyy-MM-dd HH:mm:ss.SSSSSS';
end
%% COmpare log and LSL timestamps
figure(22);clf
plot(logtrig.datetime(1:length(xdf_trig_pc1.time_stamps)),xdf_trig_pc2.time_stamps,'o' )
title([pID ' triallog vs LSL triggers'], 'interpreter','none')
xlabel('log timestamp')
ylabel('LSL timestamp')
%% Estimate PC1 absolute boot time
% subtract the LSL triggers uncorrected timestamps from the log
% timestamps, should all be the same or v similar
% note there are some weird delays introduced later in the session
% where lsl timestamps lag behind the log, so only take events upt o
% event_cutoff
event_cutoff = 30;
pc1_boot_ests = logtrig.datetime(1:event_cutoff) - ...
seconds(xdf_trig_pc2.time_stamps(1:event_cutoff))';
% how do these estimates look over time?
figure(303);clf
scatter(xdf_trig_pc1.time_stamps(1:event_cutoff),pc1_boot_ests(1:event_cutoff))
title([pID ' estimation of boot time PC1'], 'interpreter','none')
xlabel('rel timestamp (PC1)'); ylabel('estimate boot time')
% Any variability in these estimates indicates the logging and LSL
% timestamp functions are not getting the same clocktime as one another.
%
% which estimate should we use for PC1 boot time?
% -- I'd say the one derived from the earliest trigger event
% we could actually extrapolate this back in time to timestamp (PC1) ==0 if it looks like a
% simple function, or take an average over several early events
% % 1. earliest time
%pc1_boot_abs = pc1_boot_ests(1);
% 2. linear fit
pc1_boot_fn = polyfit(xdf_trig_pc1.time_stamps(1:event_cutoff),seconds(pc1_boot_ests-min(pc1_boot_ests)),1);
figure(303);hold on;
x=linspace(0,max(xdf_trig_pc1.time_stamps),100);
plot(x,seconds(x*pc1_boot_fn(1)+pc1_boot_fn(2))+min(pc1_boot_ests))
pc1_boot_abs = pc1_boot_fn(2)+min(pc1_boot_ests);
% pc1_boot_fn = polyfit(xdf_trig_pc1.time_stamps,datenum(pc1_boot_ests),1);
% figure(303);hold on;
% x=linspace(0,max(xdf_trig_pc1.time_stamps),5);
% plot(x,datetime(x*pc1_boot_fn(1)+pc1_boot_fn(2),'ConvertFrom','datenum'))
% pc1_boot_abs = datetime(pc1_boot_fn(2),'ConvertFrom','datenum','Format','yyyy-MM-dd HH:mm:ss.SSSSSS');
%% Estimate PC2 absolute boot time
% we know the offset between pc1 boot and pc2 boot for each sync - this is
% the clock_offset!
% This does seem light a tight linear relationship so let's extrapolate
% this back in time to pc2 rel ==0
% 1. get lags in terms of PC2 time
all_offset_tpc2 = all_offset_tpc1+all_offset_val;
% 2. fit linear func
offset_fn_tpc2 = polyfit(all_offset_tpc2, all_offset_tpc1,1);
x=linspace(0,max(all_offset_tpc2),5);
figure(69);clf; scatter(all_offset_tpc2, all_offset_tpc1);
hold on; plot(x,x*offset_fn_tpc2(1)+offset_fn_tpc2(2))
% 3. extrapolate back to time (PC2) ==0
pc2_boot_abs = pc1_boot_abs + seconds(offset_fn_tpc2(2));
title([pID ' estimation of boot time PC2'],'interpreter','none')
xlabel('timestamp (PC2)'); ylabel('timestamp (PC1)')
%% Load EEG using Fieldtrip
% TODO: Is the ft function modifying timestamps to start at 0 or is
% thsi in the recording?
cfg=[];
cfg.dataset = fullfile(datapath, pID, 'EEG', [pID, '.eeg']);
eeg_bv = ft_preprocessing(cfg);
%% Get EEG start time in other formats. Add this to the 0-based indexing of EEG timestamps to get it in that format
eeg_start_pc2rel = seconds(eeg_start_pc2abs-pc2_boot_abs);
eeg_start_pc1rel = offset_fn_tpc2(1)*eeg_start_pc2rel + offset_fn_tpc2(2);
eeg_start_pc1abs = seconds(eeg_start_pc1rel)+pc1_boot_abs;
eeg_start_pc1abs.Format=('yyyy-MM-dd HH:mm:ss.SSSSSS');
%% Plot EEG and triggers from log file
figure(s); clf;
subplot(2,1,1)
plot(seconds(eeg_bv.time{1,1})+eeg_start_pc1abs,eeg_bv.trial{1,1})
hold on
% plot vertical bars for the triggers
plot([logtrig.datetime'; logtrig.datetime'],...
repmat(ylim',1,length(logtrig.datetime)))
xlabel('time')
ylabel('raw EEG')
subplot(2,1,2)
plot(logtrig.datetime, logtrig.VAL, 's')
xlabel('time')
ylabel('trigger value')
sgtitle([pID ' aligned to PC1 clock'], 'interpreter','none')
%% store diagnistics
timinfo(s).eeg_start_pc1abs = eeg_start_pc1abs;
timinfo(s).eeg_start_pc2abs = eeg_start_pc2abs;
timinfo(s).eeg_start_pc1rel = eeg_start_pc1rel;
timinfo(s).eeg_start_pc2rel = eeg_start_pc2rel;
timinfo(s).pc1_boot_abs = pc1_boot_abs;
timinfo(s).pc2_boot_abs = pc2_boot_abs;
timinfo(s).eeg_start_discrepancy = seconds(eeg_start_pc2abs - eeg_start_pc1abs);
timinfo(s).pc1_boot_discrepancy = seconds(pc1_boot_ests(end) - pc1_boot_ests(1));
timinfo(s).lsl_range_offset = range_offset;
end
%% unused crap
%%
% %% get offset between pc1 boot (just running the windows comman,d this is shitty 1s resolution!) and EEG recording start (pc2)
% % note this asssumes both clocks tell the same time!
% % startup_time = '20200724083848';
% % using online converter this is equiv to
% pc1_boot_unix = 1595601528000;
% unix_offset_ms = eeg_start_unix-pc1_boot_unix;
%
%% Plot synced data
% figure(s); clf;
% subplot(2,1,1)
% plot(eeg_bv.time{1,1},eeg_bv.trial{1,1})
% hold on
% % plot vertical bars for the triggers
% plot([xdf_trig.time_stamps - unix_offset_ms/1000;...
% xdf_trig.time_stamps - unix_offset_ms/1000], ...
% repmat(ylim',1,length(xdf_trig.time_stamps)))
% xlabel('time (sec since EEG recording began)')
% ylabel('raw EEG')
% subplot(2,1,2)
% plot(xdf_trig.time_stamps - unix_offset_ms/1000, xdf_trig.time_series, 's')
% xlabel('time (sec since EEG recording began)')
% ylabel('trigger value')
%
% sgtitle([pID 'rough aligned by boot time (second resolution'], 'interpreter','none')