Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Wishlist of having bias_step time constant measurement analysis to be optional #326

Open
yuhanwyhan opened this issue Jan 6, 2023 · 0 comments

Comments

@yuhanwyhan
Copy link
Contributor

def take_bias_steps(S, cfg, bgs=None, step_voltage=0.05, step_duration=0.05,

Is it possible to add in a new argument so that the analysis of biasstep only generates R_tes? i.e. do not run the time constant fit. This is to speed up the analysis process for bias_step rebiasing script. During the bias_step rebiasing, the only product used is R_tes.

@jlashner jlashner linked a pull request Jan 23, 2023 that will close this issue
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging a pull request may close this issue.