Derive KD from multiple pt measurments
Derive KD for target-ligand complex using multiple microdialysis derived pt
values - the ratio of compound concentrations in the red versus white chamber.
"""
import numpy as np
from uncertainties import ufloat
from microdialysis_equations import *
# We can choose to work in a common unit, typically nM, or uM, as long as all
# numbers are in the same unit, the result is valid. We assume uM for all
# concentrations bellow. If uM is used for concentrations, then ul should be
# used as the standard unit for volume etc.
# - l0 is total compound, or ligand concentration over the entire volume
# if no protein was present (25 equal to starting in the red chamber
# with a conc of 100 µM if chambers are 100 and 300 ul)
# - t0 is target, or protein concentration in the red chamber, kdpc is the Kd
# of pc complex, redvol and whitevol are volumes of respective chambers.
# - redvol is the volume of the red chamber (the protein-containing chamber)
# - whitevol is the volume of the white chamber (the no protein chamber)
# - pt_mean is the mean of experimentally determined pt values representing
# the ratio of compound in the red versus white chambers.
# - pt_std is the standard deviation of experimentally determined pt values
# representing the ratio of compound in the red versus white chambers.
# - pt is a special ufloat object from the Python uncertainties package,
# which takes as arguments a mean and standard deviation. If multiple
# values are not used, then it can be a singular regular value.
# - pt_measurments is a list containing the experimentally determined pt
# values (ratio of compound concentration in red chamber versus the white
# chamber). Multiple values may be listed here, or alternatively,
# just 1.
# - pc_measurments is a list containing the experimentally derived pt values
# representing the ratio of compound in the red versus white compartment
# in the absence of protein. A perfectly equilibrating compound will have a
# pc value of 1.0. Multiple values may be listed here, or alternatively,
# just 1.
t0=80
l0=50
redvol=100
whitevol=300
pt_measurements = [1.21, 1.22, 1.20]
pc_measurements = [1.01, 1.02, 1.01]
pt = ufloat(np.mean(pt_measurements), np.std(pt_measurements))
pc = ufloat(np.mean(pc_measurements), np.std(pc_measurements))
system_parameters={v:eval(v) for v in ["t0","l0","redvol","whitevol","pc","pt"]}
print("Finding KD for the system in",system_parameters)
print(f"Kd = {qud_Kd_from_pt(**system_parameters):.4f} µM")