Enter and |\ keys are swapped on YMD75v3 #36
Comments
This should be fixed by the-via/keyboards#1424 (apparently the VIA layout data for the ISO layout was wrong, and this PCB has somewhat unusual wiring with ANSI Enter == ISO NUHS and ANSI backslash == ISO Enter, therefore switching the layout option to ANSI gives a wrong Enter mapping too). |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I recently installed VIA on my YMD75v3 and I found that the Enter key and the |\ key are swapped in VIA
I am using the firmware from
https://www.caniusevia.com/docs/download_firmware
the filename is ymdk_ymd75_rev3_via.hex
the enter key on the phisical keyboard is recognised as the |\ key
and the |\key is recognized as enter
they just need to be swapped for the layout to be correct
Same problem if I enable the ISO enter key (which is the layout that I am using)
pressing the physical enter key lights up the |\ key
same thing here but with the ANSI enter key
Please fix this.
The text was updated successfully, but these errors were encountered: