Documentation → Introduction → Quick Start
- Preparation
- Recommended drives
- Configure monitors
- Configure OSDs
- Create a pool
- Check cluster status
- Create an image
- Install plugins
- Create VitastorFS
- Get some SATA or NVMe SSDs with capacitors (server-grade drives). You can use desktop SSDs with lazy fsync, but prepare for inferior single-thread latency. Read more about capacitors here.
- If you want to use HDDs, get modern HDDs with Media Cache or SSD Cache: HGST Ultrastar, Toshiba MG, Seagate EXOS or something similar. If your drives don't have such cache then you also need small SSDs for journal and metadata (even 2 GB per 1 TB of HDD space is enough).
- Get a fast network (at least 10 Gbit/s). Something like Mellanox ConnectX-4 with RoCEv2 is ideal.
- Disable CPU powersaving:
cpupower idle-set -D 0 && cpupower frequency-set -g performance
. - Install Vitastor packages.
- SATA SSD: Micron 5100/5200/5300/5400, Samsung PM863/PM883/PM893, Intel D3-S4510/4520/4610/4620, Kingston DC500M
- NVMe: Micron 9100/9200/9300/9400, Micron 7300/7450, Samsung PM983/PM9A3, Samsung PM1723/1735/1743, Intel DC-P3700/P4500/P4600, Intel D5-P4320, Intel D7-P5500/P5600, Intel Optane, Kingston DC1000B/DC1500M
- HDD: HGST Ultrastar, Toshiba MG, Seagate EXOS
On the monitor hosts:
- Put identical etcd_address into
/etc/vitastor/vitastor.conf
. Example:{ "etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"] }
- Create systemd units for etcd by running:
/usr/lib/vitastor/mon/make-etcd
- Start etcd and monitors:
systemctl enable --now etcd vitastor-mon
- Put etcd_address and osd_network into
/etc/vitastor/vitastor.conf
. Example:{ "etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"], "osd_network": "10.200.1.0/24" }
- Initialize OSDs:
- SSD-only or HDD-only:
vitastor-disk prepare /dev/sdXXX [/dev/sdYYY ...]
. Add--disable_data_fsync off
to leave disk write cache enabled if you use desktop SSDs without capacitors. Do NOT add--disable_data_fsync off
if you use HDDs or SSD+HDD. - Hybrid, SSD+HDD:
vitastor-disk prepare --hybrid /dev/sdXXX [/dev/sdYYY ...]
. Pass all your devices (HDD and SSD) to this script — it will partition disks and initialize journals on its own. This script skips HDDs which are already partitioned so if you want to use non-empty disks for Vitastor you should first wipe them withwipefs -a
. SSDs with GPT partition table are not skipped, but some free unpartitioned space must be available because the script creates new partitions for journals.
- SSD-only or HDD-only:
- You can change OSD configuration in units or in
vitastor.conf
. Check Configuration Reference for parameter descriptions. - Start all OSDs:
systemctl start vitastor.target
Create a pool using vitastor-cli:
vitastor-cli create-pool testpool --pg_size 2 --pg_count 256
For EC pools the configuration should look like the following:
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
Add --immediate_commit none
if you added --disable_data_fsync off
at the OSD
initialization step, or if vitastor-disk
complained about impossibility to
disable drive cache.
After you do this, one of the monitors will configure PGs and OSDs will start them.
If you use HDDs you should also add "block_size": 1048576
to pool configuration.
The other option is to add it into /vitastor/config/global, in this case it will
apply to all pools by default.
vitastor-cli status
Or you can check PG states with etcdctl --endpoints=... get --prefix /vitastor/pg/state
. All PGs should become 'active'.
Use vitastor-cli (read CLI documentation here):
vitastor-cli create -s 10G testimg
After that, you can run benchmarks or start QEMU manually with this image.
If you want to use clustered file system in addition to VM or container images: