From d4e1f4b83d2cdb6f6acd3e2f95f70bf10d76dc3e Mon Sep 17 00:00:00 2001 From: Thea Flowers Date: Tue, 20 Apr 2021 23:36:23 -0400 Subject: [PATCH] user_guide: Add burn-in testing information --- user_guide/docs/index.md | 13 +++++++------ 1 file changed, 7 insertions(+), 6 deletions(-) diff --git a/user_guide/docs/index.md b/user_guide/docs/index.md index 0ee4e305..1759c10d 100644 --- a/user_guide/docs/index.md +++ b/user_guide/docs/index.md @@ -334,12 +334,13 @@ We encourage tinkering, however, we will not refund, repair, or replace any prod We have stress tested Castor & Pollux under the following conditions. These are provided for reference only; we do not guarentee that that the module will function under these conditions. -* Overvoltage from power supply: ±18 volts -* Reverse voltage from power supply: ±18 volts -* Undervoltage from power supply: ±10 volts -* Over and under voltage on inputs: ±8 volts -* Output connected to another output: ±8 volts -* Ouput shorted to ground: 60 minutes +* Continuous run time: at least 48 hours +* Overvoltage from power supply: at least ±18 volts +* Reverse voltage from power supply: at least ±18 volts +* Undervoltage from power supply: as low as ±10 volts +* Over and under voltage on inputs: at least ±8 volts +* Output connected to another output: at least ±8 volts +* Output shorted to ground: at least 60 minutes ## Acknowledgments and thanks