# SCADA is the control interface, talking and giving instructions to all PLCs
from HMI.HMI import *
class H:
def __init__(self):
# Whole PLANT
self.PLANT = HMI_plant()
self.P1 = HMI_phase()
self.P2 = HMI_phase()
self.P3 = HMI_phase()
self.P4 = HMI_phase()
self.P5 = HMI_phase()
self.P6 = HMI_phase()
# P1
self.LIT101 = HMI_LIT(1100.0,800.0,500.0,250.0)
self.MV101 = HMI_mv()
self.FIT101 = HMI_FIT(3.0,2.6,2.5,0.0)
self.P101 = HMI_pump()
self.P102 = HMI_pump()
self.P_RAW_WATER_DUTY = HMI_duty2()
# P2
self.MV201 = HMI_mv()
self.LS201 = HMI_LS()
self.LS202 = HMI_LS()
self.LSL203 = HMI_LS()
self.LSLL203 = HMI_LS()
self.P201 = HMI_pump()
self.P202 = HMI_pump()
self.P203 = HMI_pump()
self.P204 = HMI_pump()
self.P205 = HMI_pump()
self.P206 = HMI_pump()
self.P207 = HMI_pump()
self.P208 = HMI_pump()
self.P_NACL_DUTY = HMI_duty2()
self.P_HCL_DUTY = HMI_duty2()
self.P_NAOCL_FAC_DUTY = HMI_duty2()
self.FIT201 = HMI_FIT(4.0,2,0.5,0.0)
self.AIT201 = HMI_ait(950.0, 260.0, 250.0,50.0)
self.AIT202 = HMI_ait(12.0, 7.05,6.95,3.0)
self.AIT203 = HMI_ait(750.0,500.0,420.0,100.0)
# self.P3
self.Mid_P602_AutoInp = 0
self.Cy_P3 = HMI_Ultralfiltration_Cycle()
self.LIT301 = HMI_LIT(1200.0,1000.0,800.0,250.0)
self.P301 = HMI_pump()
self.P302 = HMI_pump()
self.P_UF_FEED_DUTY = HMI_duty2()
self.FIT301 = HMI_FIT(4.0,2.4,0.5,0.0)
self.PSH301 = HMI_PSH()
self.DPSH301 = HMI_DPSH()
self.DPIT301 = HMI_DPIT(101.325,40.53,10.1325,0.0)
self.MV301 = HMI_mv()
self.MV302 = HMI_mv()
self.MV303 = HMI_mv()
self.MV304 = HMI_mv()
# self.P4
self.LS401 = HMI_LS()
self.LIT401 = HMI_LIT(1200.0,1000.0,800.0,250.0)
self.P401 = HMI_pump()
self.P402 = HMI_pump()
self.P403 = HMI_pump()
self.P404 = HMI_pump()
self.UV401 = HMI_uv()
self.P_NAHSO3_ORP_DUTY = HMI_duty2()
self.P_RO_FEED_DUTY = HMI_duty2()
self.AIT401 = HMI_ait(100.0, 80.0, 0.0, 0.0)
self.AIT402 = HMI_ait(800.0, 250.0, 240.0, 200.0)
self.FIT401 = HMI_FIT(4.0,2.0,0.5,0.0)
# self.P5
self.Mid_P603_AutoInp = 0 # This a variable shared and mostly read by P6 PLC, it's not HMI variable(maybe from SCADA, people can't change),but in our current PLC coding, Phase 5 is not writing to this variable, it keeps 0 --PF
self.Cy_P5 = HMI_ReverseOsmosis_Cycle()
self.AIT501 = HMI_ait(14.0,8.0,6.0,2.0)
self.AIT502 = HMI_ait(300.0, 250.0, 0.0,0.0)
self.AIT503 = HMI_ait(500.0,260.0,250.0,0.0)
self.AIT504 = HMI_ait(15.0,10.0,0.0,0.0)
self.PIT501 = HMI_PIT(0,0,0,0)
self.PIT502 = HMI_PIT(0,0,0,0)
self.PIT503 = HMI_PIT(0,0,0,0)
self.FIT501 = HMI_FIT(4,2,1,0)
self.FIT502 = HMI_FIT(4,1.3,1.1,0)
self.FIT503 = HMI_FIT(4,0.9,0.7,0)
self.FIT504 = HMI_FIT(2,0.35,0.25,0)
self.MV501 = HMI_mv()
self.MV502 = HMI_mv()
self.MV503 = HMI_mv()
self.MV504 = HMI_mv()
self.P_RO_HIGH_DUTY = HMI_duty2()
self.P501 = HMI_VSD()
self.P502 = HMI_VSD()
# self.P6
self.LSL601 = HMI_LSL()
self.LSL602 = HMI_LSL()
self.LSL603 = HMI_LSL()
self.LSH601 = HMI_LSH()
self.LSH602 = HMI_LSH()
self.LSH603 = HMI_LSH()
self.P601 = HMI_pump()
self.P602 = HMI_pump()
self.P603 = HMI_pump()
self.FIT601 = HMI_FIT(4,3,2,0)