Due to some implementation details of the Metal C version of printf in zowe-common-c (it creates a DCB per TCB), it will not work properly with data set outputs when used from multiple TCBs.
Steps to Reproduce
Use a ZIS plug-in that spawns TCBs.
Specify a data set as output in SYSPRINT.
Print a message from the plug-in's TCB.
The plug-in message will be missing in the data set.
Expected behavior
All messages should be present in the data set.
Describe your environment
The environment is irrelevant: all Zowe versions are affected.
The text was updated successfully, but these errors were encountered:
Describe the bug
Due to some implementation details of the Metal C version of
printf
in zowe-common-c (it creates a DCB per TCB), it will not work properly with data set outputs when used from multiple TCBs.Steps to Reproduce
Expected behavior
All messages should be present in the data set.
Describe your environment
The environment is irrelevant: all Zowe versions are affected.