thermostat-kata

A rendition of Uncle Bob's Environment Controller kata, written in go.

Watch Presentation by Uncle Bob

The scenario

You've been tasked with writing software for a thermostat that will control HVAC hardware (heater, blower, air-conditioner). This hardware must be operated according to the manufacturer's specifications in order to run safely and effectively.

To effectively regulate the environment the temperature should never deviate more than 5 degrees from 70F. If the temperature is ever more than 10 degrees away from 70F then the appropriate Hi or Lo alarm must sound.

Bad news: The various hardware devices have not yet arrived so we can't connect to them yet. Good news: We have the hardware documentation! The hardware interfaces are defined as follows:

package contracts

type Thermometer interface {
	CurrentTemperature() int // Current ambient temperature rounded to the nearest degree (Fahrenheit).
}

type HVAC interface {
	SetBlower(state bool) // Turns the blower on or off.
	SetCooler(state bool) // Turns the cooler on or off.
	SetHeater(state bool) // Turns the heater on or off.

	IsBlowing() bool // Is the blower currently on or off?
	IsCooling() bool // Is the cooler currently on or off?
	IsHeating() bool // Is the heater currently on or off?
}

type Alarm interface {
	SetColdAlarm(state bool) // Turns the cold alarm on or off.
	SetHeatAlarm(state bool) // Turns the heat alarm on or off.

	ColdAlarm() bool // Is the cold alarm currently on or off?
	HeatAlarm() bool // Is the heat alarm currently on or off?
}

On and off are analogous to the go values true and false, respectively.

Rules specified by hardware manufacturer:

  • When the heater is on, the blower must also be on.
  • When the cooler is on, the blower must also be on.
  • The blower must continue to run for 5 minutes after the heater is turned off.
    • Because the heat exchanger has latent heat that must not be allowed to accumulate lest it melt the sensitive vanes.
  • The cooler must not be turned on within 3 minutes of being turned off.
    • Because the freon must be given time to re-condense lest the compressor vapor lock.

Design Questions:

  • How will the passage of time be marked?
  • How can the thermostat be developed and tested given that the hardware has not yet arrived?

To Do Items:

Basic Logic:

  • TODO: 1. on startup everything is off
  • TODO: 2. turn on cooler and blower if too hot
  • TODO: 3. nothing turns on if temp just right
  • TODO: 4. turn on heater and blower if too cold

Intermediate Logic:

  • TODO: 1. cooler turns off if too cold again
  • TODO: 2. heater turns off if too hot again
  • TODO: 3. blower stays on when cooling after heating
  • TODO: 4. blower stays on when heating after cooling

Advanced Logic:

  • TODO: 1. heater turns off but blower remains on for 5 minutes after heating
  • TODO: 2. cooler must remain off for three minutes before restart
  • TODO: 3. cooler does not turn back on after delay if not needed

Alarm Logic:

  • TODO: 1. turn on heat alarm at threshold
  • TODO: 2. turn on cold alarm at threshold
  • TODO: 3. no alarm returned if temp nominal
  • TODO: 4. no alarm returned when high temp <= nominal
  • TODO: 5. no alarm returned when low temp >= nominal