sensor monitor and control hardware/firmware for a personal economical and scalable grow system using a raspberrypi pico and standard off the shelf sensors and components.
includes nutrient mixing capabilities and monitor of the following sensors.
- air temp
- water temp
- humidity
- volatile organic compounds
- carbon dioxide
- soil moisture - see irrigation
- tds
- ec
- pH
see vids and picts for more details.
four liquid reservoirs using relay triggered solenoid valves for mixing water with up to three nutrients. User inputs nutrient tank capacity, target EC/TDS, nutrient mix ratios, and mixt interval then the system automatically mixes and fills the tank. Mix may also be triggered externally for point of use.
The tds/ec sensor can be used as a continuous monitor to ensure the water quality is within the target range and compensate for drift by adding water or nutrients.
moisture sensor monitors the grow media and can trigger irrigation. The nutrient mix can then be used to irrigate multiple grow mediums like hydroponic, aquaponic, or terrestial systems. See picopasco-water for controlling irrigation based on moisture sensor feedback.
includes temperature, humidity, co2, and volatile organic chemical (voc) sensors.
*-present state only include closed loop feedback for mixing additional relays may be added to control irrigation, air quality, and/or lighting
-
-
- quiescent (sensor only) - 0.25 watt
- maximum (all valves open with sensors scanning) - 4.00 watts* *operation limited to 1 pump at a time with relay triggering 1.75 watts
-
-
- on grid: ac to 5 volts transformer 5 watts
- off grid solar battery bank approximate 15 watts >=15000 mah
-
-
- $6.00 rp2040 pico - (pico w optional)
- $5.50 grove sht4x temp/rh
- $17.50 grove sgp30 voc/co2
- $14.00 water quality tds/ec
- $34.99 pH sensor
- $7.99 relays 5 volt spst - 4x bank
- $12.98 5 volt pumps 4x - (alt solenoid option)
(intended by firmware design but not required)
- rfm95 lora p2p
- lorae5 lorawan)
- wifi/bt/mqtt
- ✅
sensor firmware - ✅
bench verify hardware - ✅
wiring schematic and pinout - ✅
relay trigger firmware (mixing) - ✅
integrate sensor and mixing code (See V3.0+) - ✅
platformio and arduino compatible - ✅
pH sensor - pid control mix to target setpoint pH/tds/ec - firmware in process
- sx1262 lora/wan - bench testing gpio20 conflict with relay changed to 15,16,17,18 v4.0
- wifi/bt/mqtt
-
- lighting timers
- hvac triggers pid control
-
- wifi
- +lora(wan)
- mqtt
-
- local wifi/bt
- remote mobile app
-
- alternate mcu
- xiao
- esp32
- wioterm
- platformio build/flash verify
- alternate mcu
-
- example of runtime firmware output
- testing minimum response time of relays. 3 ms is the mininum trigger dwell otherwise relays fail to actuate mechanically.
- max power consumed 350 ma @ 5 volts [1.5 watt] during dry pump cycling.
- initial power on test partial vacuum build up induced syphoning effect.
- solved with shorter tube length and shorter elevation head.
- optional solenoid shut off valve in
<AND>