Values are multiplied with a standard baseline multiplier for each type.

  • Soot: 1/25 per second
  • Heavy metal: 1/50 per second
Machine Soot Poison Heavy Metal Connects to exhaust pipes?
Coker 20/s
Flare Stack 5/s 5/s, if leaded
Refinery 5/s, 70/s if on fire
256k Tank 50/s if on fire 50/s if on fire and leaded
Combination Oven 3/s x
Iron Furnace 1/s
Steel Furnace 2/s
Crucible 0.5/s for both stacks, if filled
Blast Furnace 1/s normally, 3/s with extension x
Firebox 3/s x
Fluid Heater 0.025/mB 0.025/mb, if leaded x
Combustion Generator 1/s x
Industrial Combustion Engine 0.025/mB 0.025/mb, if leaded x
Diesel Generator 0.025/mB 0.025/mb, if leaded x
Oil Heater 1/s x
Gas Turbine 0.25/mB x
Turbofan 0.05/mB x