Skip to content

The Robotic Motion Phantom application provides methods to accurately reproduce the full range and rate of patient-measured tumour motion using a robotically controlled phantom to provide precise 6 DoF geometric quality assurance for advanced radiotherapy approaches.

Notifications You must be signed in to change notification settings

Image-X-Institute/IntERAct

Repository files navigation

Time synchronised motion platform simulating tumour motion and external surface motion

A motion platform has been developed to reproduce internal-external motion to perform quality assurance tests for real-time image-guided radiotherapy systems. The aim of this project is to integrate the 1DoF vertical motion platform with 6DoF Robot Phantom to establish control of both robots under one software. The purpose of this goal is emulate tumour motion that is present during treatment such as breathing.

The 6 DoF system consists of a six-axis robotic arm (Universal Robot, UR3 or UR16), an acrylic phantom, a custom-base plate to mount the robotic phantom onto the treatment couch and a software application which controls the robotic phantom to reproduce the patient-measured tumor motion. The software provides methods to implement the appropriate sequence of transformations to accurately reproduce the full range (6 DoF translational and rotational motion) and rate of patient-measured tumour motion using the robotically controlled phantom. The set-up and motion trace repeatability of the robotic system was evaluated against the Calypso system and was shown to provide sub-mm and sub-degree accuracy and precision in translational and rotational degrees of freedom respectively. The basis of moving the 1D motion platform is the linear actuator motor, that is driven by a microcontroller.

Key Features

  • Accurate motion reproducibility for 6DoF tumour motion and 1DoF external respiratory motion.
  • A user-friendly GUI interface.
  • Design compactness.
  • Easy workflow.

Getting Started

Requirements

Documentation

The 1DoF Documentation folder contains required information to assemble a similar 1DoF system. The 6DoF Documentation folder contains required information to assemble a similar 6-DoF system: Bill of materials, CAD files for the phantom and hardware tools, robot specifications, documentation, a user-guide to operate the system, and, step-by-step QA procedure for a real-time image-guided radiotherapy technology, Kilovoltage Intrafraction Monitoring (KIM) using the robotic phantom.

Building the Robotic Motion Phantom software

The software was written and tested in C# using Visual Studio 2019 with .NET Framework 4.5 using Windows 10 64-bit, but may work with other versions of Visual Studio.

  1. Open PhantomControl.sln in Visual Studio (https://github.com/Image-X-Institute/6-DoF-Robotic-Motion-Phantom/blob/main/Program%20Files/PhantomControl.sln).
  2. Build the solution in Release mode.
  3. This will create the application PhantomControl\bin\Release\PhantomControl.exe which can then be operated using this guide when connected to a six-axis robotic system or/and one dimensionnal platform.

Publications

Clinical Trials

Clinical use

  • Adapted for routine quality assurance tests at Princess Alexandra Hospital.

Licence

Content is released under this licence which includes attribution guidelines, contribution terms, and software and third-party licences and permissions.

Limitations and safety

The UR3 robot has automated tasks up to 3 kg (6.6 lbs). It has reach radius of up to 500 mm (19.7 in) with 0.1 mm and 0.2 deg repeatability. For all other safety related issues, please visit the Universal Robot website.

Future work

Future works planned to be done with this project:

  • Phantoms with lung insert for quality assurance of the markerless tracking systems.
  • Concurrent geometric and dosimetric quality assurance with a radiation detector or films.
  • QA other real-time tracking systems such as depth sensors as used in the Remove the Mask Project.

Authors

Dr. Saree Alnaghy, Dr. Chandrima Sengupta, Kuldeep Makhija.

Contact

Chandrima.Sengupta@sydney.edu.au

Acknowledgements

The authors thank all the contributors, Dr. Andre Kyme, Dr. Vincent Caillet, Dr. Doan Trang Nguyen, Dr. Ricky O'Brien, Dr. Jeremy T. Booth and Prof. Paul J Keall for lending their valuable input and expertise leading up to the initial release. Thanks to Dr. Melissa Mail and Dr. Sara Tomka for their help in producing the licence of this software and to the Image-X team for providing valuable input in developing this repository.

About

The Robotic Motion Phantom application provides methods to accurately reproduce the full range and rate of patient-measured tumour motion using a robotically controlled phantom to provide precise 6 DoF geometric quality assurance for advanced radiotherapy approaches.

Topics

Resources

Stars

Watchers

Forks

Packages

No packages published