Notifications
You must be signed in to change notification settings - Fork 1
Production Meter Configuration
Olli edited this page Dec 11, 2023
·
1 revision
Arska can read solar power production from selected SMA and Fronius inverters
To read production data from an SMA inverter and Arska should be connected (WLAN recommended or Wifi). Arska reads production data with Modbus TCP from Ethernet or Wifi of the inverter:
- Unit Id: 3 (default 3)
- P-settings at input 2: On
- Activated: Yes
- Port: (default 502)
- Energy Meter: SMA Modbus TCP
- Host: IP address of the inverter (wifi/WLAN), just numbers and dots
- Port: 502 (should match inverter settings)
- Unit Id: 3 (should match inverter settings)
- Baseload (W): Estimated base consumption. For example, if baseload is 1000W and production is 3000W, "extra production" available is 2000W
Tested with STP8.0-3AV-40 (Sunny Tripower 8.0).
Solar power production values energy (cumulated) and current power can be read from a Fronius inverter (Solar API). To read production data from Fronius Solar API inverter and Arska should be connected (WLAN/Wifi). Arska reads production data with an HTTP/JSON queries
- Energy Meter: Fronius Solar API
- Host: IP address of the inverter (wifi/WLAN), just numbers and dots
- Port: 80 (should match inverter settings)
- Baseload (W): Estimated base consumption. For example, if baseload is 1000 W and production is 3000 W, "excess production" available is 2000 W
Tested with FRONIUS Eco 27.0-3-S.
Arska(r) Wiki, (C) Netgalleria Oy 2020-2024