Skip to content

Commit

Permalink
Fix unterminated mdx in ThinkPulse doc
Browse files Browse the repository at this point in the history
  • Loading branch information
retiutut committed Sep 18, 2024
1 parent 9e96474 commit b82214f
Showing 1 changed file with 15 additions and 13 deletions.
28 changes: 15 additions & 13 deletions website/docs/ThirdParty/ThinkPulse/ThinkPulse_Getting_Started.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,7 @@
id: ThinkPulse
title: "ThinkPulse Getting Started Guide"
---

Available exclusively worldwide only on the [OpenBCI® store](https://shop.openbci.com/products/thinkpulse-active-electrode-kit).

## About Conscious Labs
Expand Down Expand Up @@ -78,7 +79,7 @@ The following information applies specifically to Cyton and Cyton+Daisy Boards.
## How to replace ThinkPulse™ electrode prongs

Removal: Insert a small flat screwdriver where the electrode prongs seat into the electrode body. Gently pull/twist until the prongs loosen.
<br>
<br />
Installation: To install replacement prongs, insert into the electrode body and twist until secure.

## Technical Specs and Data Sheet
Expand All @@ -87,22 +88,23 @@ Installation: To install replacement prongs, insert into the electrode body and

<br />

| Parameters | Specs |
|---|---|
| Electrode Height | 7 mm |
| External Diameter | 19 mm |
| Bio-contact Area Diameter | 15 mm |
| Material | Conductive polymer |
| Polymer Dielectric Resistivity | 3.6 Ohm.cm |
| Through Polymer Resistance | &lt;70 Ohm |
| Typical Consumption | 5 mW |
| Active amplification Gain | 0 dB |
| Electrode Noise | &lt;10nV |
| Bandwidth | >10KHz |
| Parameters | Specs |
| ------------------------------ | ------------------ |
| Electrode Height | 7 mm |
| External Diameter | 19 mm |
| Bio-contact Area Diameter | 15 mm |
| Material | Conductive polymer |
| Polymer Dielectric Resistivity | 3.6 Ohm.cm |
| Through Polymer Resistance | &lt;70 Ohm |
| Typical Consumption | 5 mW |
| Active amplification Gain | 0 dB |
| Electrode Noise | &lt;10nV |
| Bandwidth | >10KHz |

<br />

## Additional Troubleshooting

When using the ThinkPulse Active Electrodes with Cyton, make sure to set the [correct channel settings](#using-the-thinkpulse-sensors-with-openbci-cyton-board). This should resolve most issues. If you still have issues, you can reach out on the [OpenBCI Forum](https://openbci.com/forum) or send us an email at [contact@openbci.com](mailto:contact@openbci.com).

You can also refer to [this resolved troubleshooting thread](https://openbci.com/forum/index.php?p=/discussion/2869/thinkpulse-active-electrodes-q-a-resolved) in the OpenBCI Technical Forum.