PepperDash Apc Plugin

The APC plugin endeavors to provide device control and routing over Apc Type Power devices.

Types

  1. Ap89xx

Join Map

Digitals

Join To Simpl From Simpl
1 Device Online -
2-50 Reserved For Future Reserved For Future
51-100 Power On Feedback Power On
100-151 - Power Off
151-200 - Power Toggle

Analogs

Join To Simpl From Simpl
1 - -
2-50 - -
51-100 - -
100-151 - -
151-200 - -

Serials

Join To Simpl From Simpl
1 Device Name -
2-50 - -
51-100 Outlet Name -
100-151 - -
151-200 - -

Join Details


  1. Outlet Name is defined by the Name property in config, and is not necesarily what will be in the APC software; and the APC software requires outlet names to no contain spaces or characters.

Config Example

{
    "key": "PowerSupply01",
    "uid": 74,
    "name": "PowerSupply01",
    "type": "Ap89xx",
    "group": "power",
    "properties": {
        "control": {
            "endOfLineString": "\n",
            "deviceReadyResponsePattern": "",
            "method": "ssh",
            "tcpSshProperties": {
                "address": "0.0.0.0",
                "port": 22,
                "autoReconnect": true,
                "AutoReconnectIntervalMs": 10000,
                "username": "apc",
                "password": "apc"
            }
        },
        "outlets":
        {
            "outlet01" : {
                "name": "My First Outlet",
                "outletIndex": 1,
                "delayOn": 30,
                "delayOff": 2
            },
            "outlet02" : {
                "name": "Another Awesome Outlet",
                "outletIndex": 4,
                "delayOn": 30,
                "delayOff": 2
            }
        }
    }
}

Config Details


Properties:

"outlets"

  • Dictionary that defines the outlets to be controlled
  • "key" - defines and sets the name of the outlet in the APC software. This value must be unique and contain no spaces or specials charaters
  • "name" - defines the name that will be sent to the bridge for a UI friendly name. If this value is not set it will be the key
  • "outletIndex" - outletNumber to be controlled
  • "delayOn" - NOT YET IMPLEMENTED
  • "delayOff" - NOT YET IMPLEMENTED

Planned Updates

  1. Create a custom StatusMonitor to get more detailed infomation
  2. Add ability to set on/off delays by outlet