This guide aims to help you configure your Proxmox hosts to support our suite of LXC and VM applications, allowing for the creation of a dependable Proxmox host.
It includes step-by-step instructions and an Easy Script Toolbox that can automate much of the work. Moreover, the "PVE Basic" add-on in the Easy Script Toolbox should be executed on all PVE hosts (both primary and secondary). This add-on contains essential PVE Container UID & GID mapping required by all Ahuacate CTs and VMs, ensuring permission rights for bind-mounted shared data are resolved.
- Step-by-step Proxmox installation instructions
- Configure PVE host networking, hostnames and DNS
- Configure network switches and VLANs
Easy Script Toolbox menu includes the following tasks.
- PVE Basic - required by all PVE hosts (mandatory/required)
- Update Proxmox
- Check and set Proxmox subscription key (free or enterprise)
- Install nbtscan SW
- Adjust sysctl parameters
- Perform PVE container (CT) mapping
- PVESM NFS Storage - add additional NFS PVE storage mounts
- PVESM SMB/CIFS Storage - add additional SMB/CIFS storage mounts
- PVE Hostname Updater - change the hostname of a node
- Fail2Ban Installer
- SSMTP Email Installer
- PVE Host Grub boot delay - set the grub boot delay
- PVE Intel Amd iGPU LXC support - allow LXC access to CPU iGPU
- PVE CT updater - mass update all CT OS
Read about our system-wide requirements before proceeding any further.
Network Prerequisites Network prerequisites are:
- Layer 2/3 Network Switches
- Network Gateway is
XXX.XXX.XXX.5
( default is 192.168.1.5 ) - Network DHCP server is
XXX.XXX.XXX.5
( default is 192.168.1.5 ) - Internet access for the PVE host
- File server or NAS (i.e NAS-01) . Our default NAS IPv4 address is
XXX.XXX.XXX.10
( default is 192.168.1.10 ) - File server or NAS configured with network shares, either CIFS or NFS, as per these guides:
- OEM (Synology) or Linux NAS build guide
- PVE hosted NAS build guide
Other Prerequisites Optional information required running specific Easy Script Toolbox add-ons.
- SMB/NAS CIFS user account credentials as per these (Only if your adding PVE storage using NAS SMB/CIFS storage mounts)
- Optional PVE Postfix
- Email account credentials
- MailGun account credentials
Before proceeding, we strongly advise that you familiarize yourself with network Local DNS and the importance of having a PiHole server. To learn more, click here.
It is essential to set your network's Local Domain or Search domain. For residential and small networks, we recommend using only top-level domain (spTLD) names because they cannot be resolved across the internet. Routers and DNS servers understand that ARPA requests they do not recognize should not be forwarded onto the public internet. It is best to select one of the following names: local, home.arpa, localdomain, or lan only. We strongly advise against using made-up names.
Easy Scripts simplify the process of installing and configuring preset configurations. To use them, all you have to do is copy and paste the Easy Script command into your terminal window, hit Enter, and follow the prompts and terminal instructions.
Please note that all Easy Scripts assume that your network is VLAN and DHCP IPv4 ready. If this is not the case, you can decline the Easy Script prompt to accept our default settings. Simply enter 'n' to proceed without the default settings. After declining the default settings, you can configure all your PVE container variables.
However, before proceeding, we highly recommend that you read our guide to fully understand the input requirements.
Before running the Easy Script Toolbox first configure your Proxmox hosts networking (Read-on).
SSH login to your PVE host ssh root@IP_address
. Then run the following command.
bash -c "$(wget -qLO - https://raw.githubusercontent.com/ahuacate/pve-host/main/pve_host_toolbox.sh)"
- 1. Prepare your Hardware
- 2. Prepare Proxmox network interfaces
- 3. Prepare network switch
- 4. File Server (NAS)
- 5. PVE Easy Script Toolbox
- 5.1. Run our PVE Host Toolbox Easy Script
- 5.2. PVE Basic
- 5.3. PVESM NFS Storage
- 5.4. PVESM SMB/CIFS Storage
- 5.5. PVE Hostname Updater
- 5.6. Fail2Ban Installer
- 5.7. SMTP Server Credentials (Recommended)
- 5.8. PVE CT updater
- 5.9. PVE Host Grub boot delay (recommended)
- 5.10. PVE Intel Amd iGPU LXC support - allow LXC access to CPU iGPU
- 6. GitHub "ttneck" helper scripts
- 7. Create a PVE Cluster
- 8. Fixes, patches & Troubleshooting
Proxmox installs on any x86 hardware with a few conditions. The hardware should have Intel NIC devices and commercial grade SSD or NVMe drives.
Your installation options are determined by your hardware specifications and requirements.
PVE hosts require 1x or 2x ethernet NIC adapters and single boot disk device. A standard PVE host can be installed as your primary or secondary PVE host for creating a PVE cluster. A minimum of two secondary PVE hosts is required to form a cluster quorum in the event a PVE host fails.
- 1x ethernet NIC - This is a standard generic build. Not suitable for hosting a pfSense VM.
- 2x or more ethernet NIC - Suitable for hosting a pfSense VM.
Go to the Proxmox website and download the latest ISO and burn it to a USB stick. Instructions are here.
In this guide, we refer to SCSi and SATA (Serial ATA) controller devices designated disk names such as sda
, sdb
, sdc
and so on, a generic Linux naming convention, as sdx
only. Ideally sda
(and sdb
) should be allocated as the Proxmox OS SSD device.
Some main boards may not show disk devices as sda/sdb/sdc
because the SSD is not installed on a SCSi or SATA controller. For example, NVMe drives show as /dev/nvme0(n1..). It's most important to check your hardware device schematics and note which device type is designated to which type of hard drive (SSD) you have installed.
Boot from the Proxmox installation USB stick and configure Proxmox VE as follows:
Proxmox Virtualization Environment (PVE) - At this stage you must select your PVE OS installation drives, Raid type and partition sizes. Click 'options' and complete as follows:
Option | Value | Notes |
---|---|---|
Filesystem - 1x SSD | ext4 or zfs (RAID0) |
Ext4 is fine. |
Filesystem - 2x SSD | ext4 or zfs (RAID1) |
Ext4 is fine. |
Disk Setup - SATA | ||
Harddisk 0 | /dev/sdx | |
Harddisk 1 | /dev/sdx | |
Disk Setup - PCIe NVMe | ||
Harddisk 0 | /dev/nvmeXn1 | |
Harddisk 1 | /dev/nvmeXn1 | |
Advanced Options | ||
ashift | 12 |
4K sector size. For 8K sectors use 13. |
compress | lz4 |
|
checksum | on |
|
copies | 1 |
|
SSD size - 240GB (or smaller) | 220 |
Over-provisioning is recommended. |
The final step is to configure a network device. If you have multiple onboard ethernet LAN NIC devices, 10GbE ethernet or a multi-port Intel PCIe LAN Card installed, you must choose one single device only to configure at this stage.
The selected device will be your LAN. If you have 10GbE ethernet, on a primary or secondary PVE host, then always select and configure the 10GbE device.
If your PVE host has only 1GbE LAN NICs then you must choose the first ethernet device ID of either an onboard mainboard Intel NIC or if available the first device of your installed Intel PCIe LAN Card. Your decision is based on how many valid (Intel brand) ethernet devices are available ignoring all other brands if you can. For example, if you have an Intel I350-T4 PCIe x4 LAN Card 4x Port installed and 2x onboard Realtek NICs, always ignore the 2x Realtek devices from all selection criteria. Try to use only Intel NICs whenever possible.
Here's a table to help you understand your options:
Port 1 | Port 2 | Port 3 | Port 4 | |
---|---|---|---|---|
Example 1 | ||||
10GbE SFP+ | ✅ | |||
Onboard x2 (Realtek) | ❌ | ❌ | ||
Intel PCIe LAN Card 4x Ports | ☑ | ☑ | ☑ | ☑ |
Example 2 | ||||
Onboard x1 (Intel) | ✅ | |||
Intel PCIe LAN Card 2x Ports | ☑ | ☑ | ||
Example 3 | ||||
Onboard x2 (Intel) | ✅ | ☑ | ||
Intel PCIe LAN Card 2x Ports | ☑ | ☑ | ||
Example 4 | ||||
Onboard x1 (Realtek) | ❌ | |||
Intel PCIe LAN Card 4x Ports | ✅ | ☑ | ☑ | ☑ |
Primary PVE hosts must be assigned hostname pve-01.local
, IPv4 address of 192.168.1.101
or at least denoted by xxx.xxx.xxx.101
.
If your want to create a pfSense OpenVPN Gateway for your network clients then you must have a minimum of 2x Intel Ethernet LAN NICs available in all PVE hosts.
The remaining steps in configuring PVE are self-explanatory. Configure each PVE host as follows.
Option | Primary Host | Secondary Host | Secondary Host | Notes |
---|---|---|---|---|
Country | Input your Country | Input your Country | Input your Country | |
Timezone | Select | Select | Select | |
Keymap | en-us |
en-us |
en-us |
|
Password | Enter your new password | Enter your new password | Enter your new password | Same user credentials on all nodes. |
Enter your Email | Enter your Email | Enter a your Email | Use a valid email address. It needs to be valid for PVE Postfix alerts and other email services to work. If you don't want to enter a valid email type mail@example.com. | |
Management interface | Leave Default | Leave Default | Leave Default | |
Hostname | pve-01.local |
pve-02.local |
pve-03.local |
Note the naming convention and use of 'local'. We recommend only top-level domain (spTLD) names for residential and small networks names because they cannot be resolved across the internet. Routers and DNS servers know, in theory, not to forward ARPA requests they do not understand onto the public internet. It is best to choose one of our listed names: local, home.arpa, localdomain or lan only. Do NOT use made-up names. |
IP Address | 192.168.1.101 |
192.168.1.102 |
192.168.1.103 |
Note the IP number assignments - XXX.XXX.XXX.101 > .102 > .103 > |
Netmask | 255.255.255.0 |
255.255.255.0 |
255.255.255.0 |
|
Gateway | 192.168.1.5 |
192.168.1.5 |
192.168.1.5 |
UniFi UGS/UDM or router. |
DNS Server 1 | 192.168.1.6 |
192.168.1.6 |
192.168.1.6 |
Set to use PiHole. |
DNS Server 2 | 192.168.1.5 |
192.168.1.5 |
192.168.1.5 |
Set to use your router static IP. |
Your LAN network switches must be L2/L3 compatible to support VLANs.
If you have extra NICs available you may consider using 802.3ad Dynamic link aggregation on these hosts too to increase bandwidth. The internet is your information source about LAGs. When considering LAGs the network switch appliance side will use 802.3ad Dynamic link aggregation (802.3ad)(LACP) so your switch must be 802.3ad compliant.
It's important the PVE Linux Bridge, Bond and VLAN naming convention is adhered to. This naming convention is used in all our Proxmox builds and Easy Scripts.
Linux Network Device names vary because they are determined by the host's mainboard (here we use enp1s0-enp01s1).
In the example below we use standard 1GBe NICs. This example is made for hosting a pfSense VM (vmbr2).
In the example below we use LAGs for illustration purposes only. This example is also made for hosting a pfSense VM.
Configure a PVE Linux Bridge vmbr0
using a single 1GbE, 10GbE, or a PVE Linux Bond.
The input name vmbr0
is critical.
Linux Bridge | |
---|---|
Name | vmbr0 |
IPv4/CIDR | 192.168.1.101/24 |
Gateway (IPv4) | 192.168.1.5 |
IPv6/CIDR | Leave blank |
Gateway (IPv6) | Leave blank |
Autostart | ☑ |
VLAN aware | ☑ |
Bridge ports | Input your NIC name (i.e enp1s0) |
Comment | Default LAN |
MTU | 1500 |
PVE pfSense VM requires 2x ethernet NICs. A LAN and a WAN (VPN-egress).
Configure a PVE Linux Bridge vmbr0
and vmbr2
using a single 1GbE, 10GbE, or a PVE Linux Bond. The fastest NIC should be assigned to vmbr0
.
The input names vmbr0
abd vmbr2
are critical.
Linux Bridge | ||
---|---|---|
Name | vmbr0 |
vmbr2 |
IPv4/CIDR | 192.168.1.101/24 |
Leave blank |
Gateway (IPv4) | 192.168.1.5 |
Leave blank |
IPv6/CIDR | Leave blank | Leave blank |
Gateway (IPv6) | Leave blank | Leave blank |
Autostart | ☑ |
☑ |
VLAN aware | ☑ |
☑ |
Bridge ports | Input your NIC name (i.e enp1s0) | Input your NIC name (i.e enp1s1) |
Comment | Default LAN |
VPN-egress |
MTU | 1500 | 1500 |
These instructions are based on an UniFi US-24 port switch. Just transpose the settings to whatever brand of Layer 2/3 Switch you use.
We use VLANs to separate networks for easier management and to apply security policies.
The first step is to edit your default LAN network configuration.
Navigate using the UniFi controller web interface to Settings
> Networks
> Create New Network
and complete as follows.
Description | Default |
---|---|
Network Name | Default |
GatewayIP/Subnet | ☐ Auto Scale Network |
192.168.1.5/24 |
|
Advanced Configuration | manual |
Network Type | ☑ Standard ☐ Guest |
IGMP Snooping | ☑ Enable |
Multicast DNS | ☐ Enable |
Network Group | LAN |
DHCP | |
DHCP Mode | DHCP Server |
DHCP Range | 192.168.1.150 -192.168.1.250 |
DHCP Service Management | |
DHCP DNS Server | ☑ Enabled |
192.168.1.6 (Pi-Hole) |
|
1.1.1.1 |
|
DHCP Default Gateway | ☑ Auto |
DHCP Lease Time | 86400 |
Domain Name | local |
IPv6 | |
IPv6 Interface Type | ☑ None ☐ Static ☐ Prefix |
Create a dedicated VLAN2 network for pfSense WAN only (labeled VPN-egress). All pfSense VPN traffic will exit pfSense on WAN VLAN2. For added security, we assign VLAN2 Guest status.
Navigate using the UniFi controller web interface to Settings
> Networks
> Create New Network
and complete as follows.
Description | VPN-egress |
---|---|
Network Name | VPN-egress |
GatewayIP/Subnet | ☐ Auto Scale Network |
192.168.2.5/28 |
|
Advanced Configuration | manual |
VLAN ID | 2 |
Network Type | ☐ Standard ☑ Guest |
IGMP Snooping | ☑ Enable |
Multicast DNS | ☐ Enable |
Network Group | LAN |
DHCP | |
DHCP Mode | DHCP Server |
DHCP Range | 192.168.2.1 -192.168.2.14 |
IPv6 | |
IPv6 Interface Type | ☑ None ☐ Static ☐ Prefix |
In UniFi you must assign the 2x physical LAN cables connecting your UniFi switch to your Proxmox host or pfSense device with a UniFi Port Profile. Both LAN and WAN connections must be identified. For cable management I dedicate switch ports 1-6 to my Proxmox cluster.
Navigate using the UniFi controller web interface to Devices
> Select switch device
> Port Management
and then select the switch port which is physically connected and assigned to Proxmox host or pfSense as LAN.
My Proxmox and pfSense "LAN" is a port aggregate of UniFi NIC ports 1 & 2 which is not a requirement.
What important is the UniFi Port Profile
of your selected NIC port must be assigned as All
.
Navigate using the UniFi controller web interface to Devices
> Select switch device
> Port Management
and then select the switch port which is physically connected and assigned to pfSense as WAN (VPN-egress).
My pfSense "WAN" is a port aggregate of UniFi NIC ports 3 & 4 which is not a requirement.
What important is the UniFi Port Profile
of your selected NIC port must be assigned as VPN-egress
.
A network-accessible file server (NAS) that supports NFS and/or CIFS sharing protocol is required. Proxmox provides storage to VMs by creating a CIFS or NFS backend storage pool by mounting your NAS export shares points.
Your PVE host must be allowed to mount all CIFS or NFS shares automatically.
A NAS of any brand or type (Synology, OMV, QNap, FreeNAS, Windows or Linux server). The NAS must support SMB3, NFSv4 and ACL services. Our NAS default IPv4 address is 192.168.1.10.
A PVE based NAS uses a ZFS or LVM Raid backend storage pool hosted on a Proxmox host (preferred pve-01).
Frontend management and NAS services are by a our own PVE Ubuntu CT (hostname label NAS-01). NAS-01 fully supports SMB3, NFSv4.1 and ACL services. A detailed guide with build options is available here.
Our Easy Script Toolbox will configure your PVE hosts to support Ahuacate CTs and VMs. Each Toolbox script will create, modify and change system settings including:
- PVE Basic - required by all PVE hosts (mandatory / required)
- Update Proxmox
- Check and set Proxmox subscription key (free or enterprise)
- Install nbtscan SW
- Adjust sysctl parameters
- Set PVE container (CT) mapping
- Set '/etc/vzdump.conf' variable to
tmpdir: /tmp
- PVESM NFS Storage - add additional NFS PVE storage mounts
- PVESM SMB/CIFS Storage - add additional SMB/CIFS storage mounts
- PVE Hostname Updater - change the hostname of a node
- Fail2Ban Installer
- SMTP Email Setup
- PVE CT updater
The available options vary between PVE primary and secondary hosts.
To execute SSH into your PVE host ( i.e. ssh root@192.168.1.101
) or use the Proxmox web interface CLI shell pve-0x
> >_ Shell
and cut & paste the following into the CLI terminal window and press ENTER:
bash -c "$(wget -qLO - https://raw.githubusercontent.com/ahuacate/pve-host/main/pve_host_setup_toolbox.sh)"
You must run this script on all primary and secondary hosts before deployment.
Add NFS storage mounts which are required by our suite of CT and VM applications. You must have the following NAS exports including linux share permissions as shown here.
Read about your HARDMETAL NAS and PVE-NAS build and configure options.
You may combine NFS and CIFS storage mounts on your PVE primary host. I use NFS only.
Add SMB/CIFS storage mounts which are required by our suite of CT and VM applications. You must have the following NAS exports including linux share permissions as shown here.
Read about your HARDMETAL NAS and PVE-NAS build and configure options.
You may combine NFS and CIFS storage mounts on your PVE primary host. I use NFS only.
Change or edit your PVE node hostname.
Fail2Ban is an intrusion prevention software framework that protects computer servers from brute-force attacks.
Most commonly this is used to block selected IP addresses that may belong to hosts that are trying to breach the systems security. It can ban any host IP address that makes too many login attempts or performs any other unwanted action within a time frame defined by the PVE administrator.
Our default Fail2ban configuration sets the following rule sets:
-
PVE WEBGUI HTTP(S) ACCESS Maximum HTTP retry 3 attempts. PVE HTTP(S) ban time is 1 hour. If your PVE Postfix SMTP server is configured then Fail2ban will send send email alerts.
-
PVE EMAIL ALERTS Send email alerts of banned login attempts. (requires working PVE Postfix SMTP server)
You have the option to configure a Postfix SMTP Email server. SMTP is Mail Transfer Agent (MTA) used to send email alerts about your machines like details about new user accounts, unwarranted login attempts, and system critical alerts to the system's designated administrator. The SMTP server is required for any PVE CT or VM which requires a email service.
You will be asked for the credentials of your SMTP Server. You can use Gmail, GoDaddy, AWS, Microsoft or any SMTP server credentials (i.e address, port, username and password, encryption type etc.
But we recommend you create an account at mailgun.com to relay your NAS system emails to your designated administrator. With MailGun you are not potentially exposing your private email server credentials held within a text file on your PVE host. This is an added layer of security.
The script performs an OS update on all PVE CTs. All CTs are returned to their former run state in the background before moving on to CT.
All your PVE hosts depend on your NAS and other network devices such as routers, DNS, DHCP servers and LAN switches. In the event of a power outage, we need your PVE hosts to be the last online.
Our solution is to edit the 'grub timeout' parameter and apply a delay of 300 seconds.
Your Proxmox server now waits 5 minutes before starting the OS, by which time your NAS and network devices (i.e switches, DNS servers) should be operational. There will be no more manual restarting of virtual machines following a power outage.
Setup Intel or AMD iGPU video render to support your LXC. Required by Jellyfin and Tdarr or any LXC performing video rendering.
tneck has a lot of helpful scripts to help you with your Homelab and Proxmox. More information here.
For tuning your Proxmox hosts I use these:
- Proxmox VE Tools
- Proxmox VE Processor Microcode
- Proxmox VE CPU Scaling Governor
Proxmox requires a minimum of three PVE hosts on the same network to form a cluster - PVE-01, PVE-02 and PVE-03.
Using the PVE web interface on host PVE-01, go to Datacenter
> Cluster
> Create Cluster
and fill out the fields as follows:
Create Cluster | Value | Notes |
---|---|---|
Cluster Name | pve-cluster |
|
Ring 0 Address | Leave Blank |
And Click Create
.
The first step in joining other nodes to your cluster, pve-cluster
, is to copy PVE-01 cluster manager fingerprint/join information into your clipboard.
Step One:
Using PVE web interface on host PVE-01, go to Datacenter
> Cluster
> Join Information
and a new window will appear showing Cluster Join Information
with the option to Copy Information
into your clipboard. Click Copy Information
.
Step Two:
Using the PVE web interface on the OTHER hosts, PVE-02/03/04, go to Datacenter
> Cluster
> Join Cluster
and a new window will appear showing Cluster Join
with the option to paste the Cluster Join Information
into an Information
field. Paste the information, enter your root password into the Password
field and the other fields will automatically be filled.
And Click Join
. Repeat for on all nodes.
All PVE host management can be performed from the PVE-01 node. Using the PVE web management WebGUI (https://192.168.1.101:8006) all added cluster hosts should be listed below Datacenter (pve-cluster)
. Or type pvecm status
into any host pve-01
> >_Shell
:
pvecm status
# Results ...
Quorum information
------------------
Date: Mon Jul 22 13:44:10 2019
Quorum provider: corosync_votequorum
Nodes: 3
Node ID: 0x00000001
Ring ID: 1/348
Quorate: Yes
Votequorum information
----------------------
Expected votes: 3
Highest expected: 3
Total votes: 3
Quorum: 2
Flags: Quorate
Membership information
----------------------
Nodeid Votes Name
0x00000001 1 192.168.1.101 (local)
0x00000002 1 192.168.1.102
0x00000003 1 192.168.1.103
If you make a mistake when setting up your cluster the following should reset your cluster settings to the PVE default.
systemctl stop pve-cluster
pmxcfs -l
rm -f /etc/pve/cluster.conf /etc/pve/corosync.conf
rm -f /etc/cluster/cluster.conf /etc/corosync/corosync.conf
systemctl stop pve-cluster
rm /var/lib/pve-cluster/.pmxcfs.lockfile
rm -f /etc/corosync/authkey
systemctl start pve-cluster
systemctl restart pvedaemon
systemctl restart pveproxy
systemctl restart pvestatd
reboot
If you experience permission errors or encounter failures when PVE (Proxmox Virtual Environment) attempts to write temporary files during the creation of a container backup, the issue may be attributed to permission problems when PVE generates temporary files. To resolve this, execute the following command on all PVE hosts:
# Set /etc/vzdump.conf tmp dir
sed -i -r '/^#?tmpdir:.*/c\tmpdir: \/tmp' /etc/vzdump.conf
Or you could edit the /etc/vzdump.conf
using nano:
tmpdir: /tmp
#dumpdir: DIR
#storage: STORAGE_ID
#mode: snapshot|suspend|stop
#bwlimit: KBPS
#performance: [max-workers=N][,pbs-entries-max=N]
#ionice: PRI
#lockwait: MINUTES
#stopwait: MINUTES
#stdexcludes: BOOLEAN
#mailto: ADDRESSLIST
#prune-backups: keep-INTERVAL=N[,...]
#script: FILENAME
#exclude-path: PATHLIST
#pigz: N
#notes-template: {{guestname}}