VirtualMCP

VirtualMCP is a small utility program able to simulate a real MCP483 or MCP310 in a Sinumerik 840D environment

header

web page: alxcor.github.io/virtualmcp.

VirtualMCP

Simulator for MCP483 or MCP310 (Control Panels for Sinumerik 840D series CNC)

VirtualMCP is a small utility program able to simulate a real MCP483 or MCP310 in a Sinumerik 840D environment.

The program may be used to control a real Sinumerik when the actual MCP is not accessible or in a remote location.

Connection

Connection

For actual version: connection possible only via TCP/IP

  • PLC Address: set here the TCP/IP address of the target system (Sinumerik system)
  • Rack: Step7 rack of the CPU (usually Rack 0).
  • Slot: Step7 slot of the CPU. Slot 2 for Sinumerik 840Dsl series with S7-300 series PLC or Slot 1 for Sinumerik ONE with S7-1500 series PLC.Slot 0 for S7-1500

Connect to a target system: Click the 'Connect' button.

MCP I/O Addresses

Connection

Settings for connection: MCP Input and Output addresses:

  • MCP1: I/O addresses of the first MCP.
  • MCP2: I/O addresses of the 2-nd MCP.
  • Act.: I/O addresses used by VirtualMCP. Editable fields.

For a Sinumerik CNC, the Machine Control Panel (MCP) is considered an Input/Output board of the PLC. In a simplified view we may consider the keys, the Override switches and the 'Access Key' 'connected' to Inputs of the PLC and the LED's of the keys controlled bu PLC outputs.

In order to configure the MCP, the Manufacturer of the machine (OEM) has to define the number of panels used and the corresponding I/O addresses of the MCP boards by parameterize the FB1,DB7 call in the OB100.

On each connection to the PLC, VirtualMCP program set itself in 'Read-Only' Mode, then reads the number of MCP's and the pointers to the first Input and Output address of the MCP from the DB7. If Act. addresses do not correspond either to MCP panel 1 or MCP panel 2 addresses, the program remains in READ-ONLY mode.

Note It is not unusual for the OEM to use a DB area instead of Inputs and Outputs for the MCP, as in the image.

Read Only Mode / Control Mode

Connection

In 'Read-Only' mode, the program is reading the status of keys, override switches, LEDs, etc from the real system without altering the data.

You may activate the 'Control' Mode for keys by pressing (Click) the 'Read-Only / Control' button.

Save

Connection

Save settings with "Save" button

More Settings

When "Save" button is clicked, all settings are saved in "monitor.ini" file located in the same folder as the Exe File.

All settings may be altered in this file and will be activated when the program is started.


[display]                ;Various settings for display
language=0               ;0 = Romana; 1 = English
stayontop=0              ;0 = Stay on Top deactivated; 1 = Stay on Top activated
displ_time=50            ;Screen refresh every 50ms

[connection]             ;Various settings for connection
autoreconnect=false      ;When true: If connection is lost or not possible, the software will try again until a connection is done
reconnect_time=5         ;Number of seconds between two connection attempts

[server]                 ;PLC CPU address
address=192.168.214.1    ;PLC CPU IP Address
rack=0                   ;PLC CPU Rack number, default 0
slot=2                   ;PLC CPU Slot number, default 0 for S7-1500 or 2 for S7-300

[address]
in_0_type=I  ;[I/Q/M/DB] ;Operand type for the first column: inputs
in_0_dbno=0  ;[number]   ;DB number, for OperandType = DB
in_0_addr=0  ;[number]   ;Byte number
out_0_type=Q ;[I/Q/M/DB] ;Operand type for the 2nd column: outputs
out_0_dbno=0 ;[number]   ;DB number, for OperandType = DB
out_0_addr=0 ;[number]   ;Byte number


Versions:

  • v23.01.24: Added widget scalability.
  • v20.05.26: Correct some issues related to font size.
  • v20.05.23: MCP Settings (number of MCP modules and MCP addresses) are read from online system on connection.
  • v20.05.14: Simulate MCP483, MCP310; selection of 'Read-Only' or 'Control Keys' sau 'Control Keys and Override'.

- The project uses Snap7 under LGPL3 License to communicate with the Sinumerik/Sinamics/Step7 equipment. - The project uses Qt under LGPL3 License.