20 changes: 19 additions & 1 deletion sdrf-proteomics/README.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -239,8 +239,26 @@ TIP: If the SDRF do not specified the proteomics data acquisition method as _com

You can find an example of a DIA experiment in the following link: https://github.com/bigbio/proteomics-sample-metadata/blob/master/annotated-projects/PXD018830/PXD018830-DIA.sdrf.tsv[DIA example]

[[dia]]
==== Data Independent Acquisition - Scan window limits

Additionally to the general _comment[proteomics data acquisition method]_ column, the SDRF-Proteomics file format allows to capture other properties for the DIA method. The following properties are RECOMMENDED for DIA:

- _comment[scan window lower limit]_
- _comment[scan window upper limit]_

The scan window lower and upper limits are the m/z range used for the DIA acquisition. The values are expressed in m/z units.

Example:

|===
| | assay name | comment[scan window lower limit] | comment[scan window upper limit] | comment[data file]
|sample 1| run 1 | 400 m/z | 1200 m/z | FILE_R1.RAW
|sample 1| run 2 | 400 m/z | 1200 m/z | FILE_R2.RAW
|===

[[instrument]]
==== Type and Model of Mass Spectrometer
=== Type and Model of Mass Spectrometer

The model of the mass spectrometer SHOULD be specified as _comment[instrument]_. Possible values are listed under https://www.ebi.ac.uk/ols/ontologies/ms/terms?iri=http%3A%2F%2Fpurl.obolibrary.org%2Fobo%2FMS_1000031&viewMode=All&siblings=false[instrument model term].