The write_timeout specified for an EpicsSignalBase is respected by its set() method unless overridden with set(..., timeout=TIMEOUT).
Area Detector PVs related to array shape have been given an order compatible with the numpy array index ordering of the array itself.
Thread the keyword EpicsSignal.get(..., use_monitor=True) down to the control system. This setting was previously supported but support was removed (years ago). We now view its removal as a mistake.
When area detector takes a series of images and num_capture is set to 0, this is now interpreted to mean “however many images the detector is configured to acquire” rather than “0 images”.
Motor limits HLS and LLS used EpicsSignal when they should be using EpicsSignalRO.
EpicsSignal with string=True kwarg now correctly results in dtype='string' from .describe() method
Added
Support for Emergent Vision detectors.
The class-wide default for write_timeout is now configurable via EpicsSignalBase.set_defaults(). It was previously only configurable on a per-instance basis at initialization time, with the class-wide default hard-coded to None. The class-wide default is still None, unchanged from the previous release.
The class-wide default for auto_monitor is now configurable via EpicsSignalBase.set_defaults(). It was previously configurable on a per-instance basis at initialization time. The default value, False, has not changed.
Changes
The logging has been tweaked to be less noisy, particularly at import time. Some log messages have been moved from 'ophyd.object' to 'ophyd.control_layer', and the level of messages emitted to 'ophyd.control_layer' have been reduced from INFO to DEBUG. Some log messages have been removed entirely.
The method EpicsSignalBase.set_default_timeout() has been renamed to EpicsSignalBase.set_defaults() because it has been extended to include more than timeouts, as described above. The old name is still supported but issues a warning that it may be removed in the future.
Use auto-monitoring in more places in EpicsMotor. This should drastically speed up motor.read_configuration().
Update ophyd.sim.MockFlyer to use its name as its stream name.
Capture the create_directory signal on Area Detector FilePlugin as configuration.