Notifications
You must be signed in to change notification settings - Fork 51
TSS Polymorphic
Let's try to validate the following assignments where mult
is a
multiplier, mod
is a modulus unit, and r
is a register:
wires {
mult.go = 1;
mult.left = 10;
mult.right = r.out;
mod.go = mult.done;
mod.left = mult.out;
mod.right = 20;
}
The example attempts immediately use the value generated by the multiplier
(mult.out
) in the computation of the mod
.
For this to work, the drive requirement for mod.left
must be less than the
amount of time mult.out
is driven for.
For example, if mult.out
is driven for one cycle but mod.left
is required
for two cycles, this program will be invalid.
First, here is the interface for mult
(mod
has the same interface):
component mult<G, @static(L)>(@hold(G, G+L) go,
@hold(G, G+1) left,
@hold(G, G+1) right) ->
(@hold(G+L, G+L+1) done,
@hold(G+L, G+L+1) out);
There are three components in this interface:
-
G
: A callee parameter that states which cyclemult
starts its execution in. In type systems land,G
is universally quantified. -
L
: The latency of themult
unit. In type systems land,L
is existentially quantified. -
@hold(G, G+1)
: The drive requirement (resp. guarantee) for inputs (resp. outputs). States that the signal is driven between cyclesG
andG+1
.
To check the program, we'll generate constraints for each assignment.
Starts the execution of the dataflow pipeline. This generates an instantiation constraint:
m0 = mult[G = 0]
The constraint states that this use of the hardware instance mult starts
at cycle 0
.
In general, each hardware instance can have multiple uses.
Next, it generates a constraint from the drive requirement of the go
signal:
[m0.G, m0.G + m0.L] = [0, 0 + ∞]
The right hand side, [0, 0 + ∞]
specifies the drive guarantee of the constant
1
which is available starting the first cycle till the end of the execution.
The constraint is a strict equality—the go
signal must not be driven after
the done
signal is set to high.
In this example, the constraint cannot be satisfied since the signal 1
will
continue driving the module forever. This is a bug in our design!
This generates drive constraint:
[m0.G, m0.G + 1] ⊆ [0, 0 + ∞]
The constraint in this case is containment—the left
signal must be driven
at least as long as the requirement states.
Driving it more than required is not an error.
Same constraint as previous assignment because the out
signal on registers
is driven forever.
This might lead to some complexity in the future when writes to registers happen during the dataflow execution.
This assignment uses the done
signal from the multiplier to start the
execution of the mod
unit.
Again, this will generate both an instantiation constraint and a drive
constraint:
m1 = mod[G = m0.G + m0.L]
Since the mod
unit uses the signal from the m0
use of the mult
unit, it
is instantiated using constraints from that use.
The drive constraint is:
[m1.G, m1.G + m1.L] = [m0.G + m0.L, m0.G + m0.L + 1]
The right hand side is derived from the drive guarantee of the mult.done
signal which is live for one cycle after the execution of the unit.
Again, the constraint demands strict equality and again the right hand
side fails.
Yet another bug vanquished by the type system.
The assignment generates a drive constraint:
[m1.G, m1.G + 1] ⊆ [m0.G + m0.L, m0.G + m0.L + 1]
This constraint is valid since m1.G = m0.G + m0.L
. The type system has
proved that the chained use of mult.out
is correct!
The final assignment demonstrates why the weaker, containment requirement is useful for input signals:
[m1.G, m1.G + 1] ⊆ [0, 0 + ∞]
The constant signal 20
is always driven which means that mod.right
can
safely read from it.