Skip to content

Unofficial api documentation and web interface to control "Daikin Emura" air conditioner

License

Notifications You must be signed in to change notification settings

glfp/daikin-control

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

79 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Daikin-Control

Web Gui Preview

The '''Daikin Emura FTXG-L''' air conditioner comes with a wifi module preinstalled that allows you to control it via internet. The solution provided by Daikin is a mobile app (very well designed) that allows you to control the air conditioner even remotely, exploiting the REST API of the wifi module.

Even if the system works, there are some problems:

  • It is no possible to control the AC from a web browser. You must use the official mobile application. If your device is not supported or you are from a computer you can not control your air conditioner over the internet.
  • To control your AC remotely from outside your lan, your requests must go through the Daikin server. The device response is slow because the system is based on polling request. (you can't set the ip of the AC on the mobile application)
  • Even if the remote management system involves the use of an account with password, there is a big security issue, password and username can be accessed from inside your LAN with a GET request. (try basic_info request)

This project aims to provide 2 main things:

  • unoffcial documentation of Daikin API needed to control the air conditioner
  • web interface to manage air conditioner settings

Tested Hardware

The API described by this document have been tested and seems to be working with firmware version from 1.4.3 to 3.3.1.

The following hardware configurations have been used for testing:

ModelName:          Daikin Emura FTXG-L
ModelID:            FTXG35LV1BW
WifiControllerID:   BRP069A41 4P358711-2C
Software version:   1.4.3
ModelName:          Daikin Emura FVXS-F
ModelID:            FVXS35FV1B
WifiControllerID:   BRP069A42
Software version:   2.6.0
ModelName:          Daikin Caldo XRH30
ModelID:            FTXTM302V1B
WifiControllerID:   BRP069B41
Software version:   1.2.51

If you try new hardware configurations or new firmware versions, please contact me.

API System

Daikin original API use REST.

You can use GET http request to retrive informations and POST http request to apply new settings.

Uri GET POST desc
/common/basic_info X Provides Daikin account information (security issue!), software version, mac address and generic info
/common/get_remote_method X Provides information about polling system
/common/set_remote_method X Set information on the polling system (reduce remote time update ??)
/aircon/get_model_info X Provides model informarion
/aircon/get_control_info X Main Uri to request all current status parameters
/aircon/set_control_info X X Main Uri to set status parameters (control almost all)
/aircon/get_sensor_info X Provides information on sensors (temperatures, humidity, power consumption)
/aircon/get_timer X ?
/aircon/set_timer X ?
/aircon/get_price X ?
/aircon/set_price X ?
/aircon/get_target X ?
/aircon/set_target X ?
/aircon/get_week_power X Provides weekly and today runtime information (in mn)
/aircon/get_year_power X Provides yearly runtime information
/aircon/get_program X ?
/aircon/set_program X ?
/aircon/get_scdltimer X Provides information about on/off weekly timer
/aircon/set_scdltimer X Set information about on/off weekly timer
/common/get_notify X ?
/common/set_notify X ?
/common/set_regioncode X ?
/common/set_led X ?
/common/reboot X reboot the AP

Parameters

/aircon/set_control_info

Power

param name : pow

description: represents the power state of the device

value desc
0 OFF
1 ON

Mode

param name : mode

description: represents the operating mode

value desc
2 DEHUMDIFICATOR
3 COLD
4 HOT
6 FAN
0-1-7 AUTO

Temp

param name : stemp

description: represents the target temperature

general accepted range 10-41

mode accepted range
AUTO 18-31
HOT 10-31
COLD 18-33

device memorize last target temp state for each mode under dft* (dft1,dft2...) parameters. You can't set directly these.

Fan rate

param name : f_rate

description: represents the fan rate mode

Daikin Emura FVXS does not support silence (=B) value for fan rate mode functionality.

value desc
A auto
B silence
3 lvl_1
4 lvl_2
5 lvl_3
6 lvl_4
7 lvl_5

device memorize last fan rate state for each mode under dfr* (dfr1,dfr2...) parameters. You can't set directly these.

Fan direction

param name : f_dir

description: represents the fan direction

value desc
0 all wings stopped
1 vertical wings motion
2 horizontal wings motion
3 vertical and horizontal wings motion

device memorize last fan rate state for each mode under dfd* (dfd1,dfd2...) parameters. You can't set directly these.

Humidity

param name : shum

description: represents the target humidity

Daikin Emura FTXG-L and FVXS does not support humidity related functionality.

device memorize last humidity state for each mode under dh* (dh1,dh2...) parameters. You can't set directly these.


Minimal parameters set

The /aircon/set_control_info has some mandatory parameters, it means that you need to include them in all the requests to this endpoint even if you are not interested in changing those specific values.

These are the mandatory parameters:

  • pow
  • mode
  • stemp
  • shum
  • f_rate
  • f_dir

While these are the ones that can be omitted:

  • adv
  • dt*
  • dh*
  • dfr*
  • dfd*
  • b_mode
  • b_stemp
  • b_shum
  • b_f_rate
  • b_f_dir
  • alert

minimal request example: pow=1&mode=1&stemp=26&shum=0&f_rate=B&f_dir=3

/common/set_led

Led

It seems that this settings doesn't actually change led.

param name: led

value desc
  • | set to '0' (same as '0' value) 0 | ? 1 | ?

Unsupported settings

This list show which hardware functionality are not supported by API

  • led brightness switch

Libraries

Useful resource

Control Info Examples

Switched Off

ret=OK,pow=0,mode=7,adv=,stemp=24.0,shum=0,dt1=24.0,dt2=M,dt3=25.0,dt4=25.0,dt5=25.0,dt7=24.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=7,b_stemp=24.0,b_shum=0,alert=255,f_rate=4,f_dir=0,b_f_rate=4,b_f_dir=0,dfr1=4,dfr2=5,dfr3=7,dfr4=5,dfr5=5,dfr6=5,dfr7=4,dfrh=5,dfd1=0,dfd2=0,dfd3=3,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0

Auto 25C ( CONFORT AIR ) ( INTELLIGENT EYE )

ret=OK,pow=1,mode=7,adv=,stemp=25.0,shum=0,dt1=25.0,dt2=M,dt3=22.0,dt4=25.0,dt5=25.0,dt7=25.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=7,b_stemp=25.0,b_shum=0,alert=255,f_rate=A,f_dir=0,b_f_rate=4,b_f_dir=0,dfr1=4,dfr2=5,dfr3=4,dfr4=5,dfr5=5,dfr6=5,dfr7=4,dfrh=5,dfd1=0,dfd2=0,dfd3=0,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0
ret=OK,pow=1&dh2=50&dfd4=0&b_stemp=25.0&alert=255&f_dir=0&b_shum=0&dh4=0&dfd3=0&dh3=0&dfd2=0&dfr2=5&dfr7=B&dfr4=5&dfd7=0&dfrh=5&dt3=25.0&dfdh=0&adv=&dh5=0&dh1=0&dfr6=5&dt5=25.0&dfr1=B&stemp=25.0&shum=0&dfd6=0&f_rate=A&b_f_dir=0&dt1=25.0&dhh=50&dfd1=0&dfr3=5&dh7=0&mode=1&dfd5=0&b_mode=7&dt4=25.0&b_f_rate=A&dt7=25.0&dt2=M&dfr5=5

Hot 25c ( AIR silence )

ret=OK,pow=1,mode=4,adv=,stemp=25.0,shum=0,dt1=25.0,dt2=M,dt3=22.0,dt4=25.0,dt5=25.0,dt7=25.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=4,b_stemp=25.0,b_shum=0,alert=255,f_rate=B,f_dir=0,b_f_rate=B,b_f_dir=0,dfr1=B,dfr2=B,dfr3=B,dfr4=B,dfr5=B,dfr6=B,dfr7=B,dfrh=5,dfd1=0,dfd2=0,dfd3=0,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0

About

Unofficial api documentation and web interface to control "Daikin Emura" air conditioner

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • HTML 69.6%
  • JavaScript 25.4%
  • PHP 4.8%
  • Shell 0.2%