doc: update known SDC issues
Browse files Browse the repository at this point in the history
Adds known bugs with tags to previous NCS versions

Signed-off-by: Olivier Lesage <olivier.lesage@nordicsemi.no>
  • Loading branch information
olivier-le-sage authored and jfischer-no committed Jun 22, 2021
1 parent cb816a9 commit 36192f9
Showing 1 changed file with 130 additions and 18 deletions.
148 changes: 130 additions & 18 deletions doc/nrf/known_issues.rst
Original file line number Diff line number Diff line change
Expand Up @@ -1025,6 +1025,95 @@ KRKNWK-8133: CSMA-CA issues
SoftDevice Controller
=====================

.. rst-class:: v1-6-0 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0

DRGN-15852: In rare cases on nRF53 Series devices, an assert can occur while scanning
This only occurs when the host started scanning using HCI LE Set Scan Enable.
This is default configuration of the Bluetooth host.

**Workaround:** Use extended scanning commands.
That is, set :option:`CONFIG_BT_EXT_ADV` to use HCI LE Set Extended Scan Enable instead.

.. rst-class:: v1-6-0 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0

DRGN-15852: In rare cases on nRF53 Series, the scanner generates corrupted advertising reports
The following fields are affected:

* Event_Type
* Address_Type
* Direct_Address_Type
* TX_Power
* Advertising_SID

.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15586: "HCI LE Set Scan Parameters" accepts a scan window greater than the scan interval
This can result in undefined behavior. It should fail with the result "Invalid HCI Command Parameters (0x12)".

**Workaround:** The application should make sure the scan window is set to less than or equal to the scan interval.

.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0

DRGN-15547: Assertion when updating PHY and the event length is configured too low
The SoftDevice Controller may assert if:

* :c:union:`sdc_cfg_t` with :c:member:`event_length` is set to less than 2500 us and the PHY is updated from 2M to 1M, or from either 1M or 2M to Coded PHY.
* :c:union:`sdc_cfg_t` with :c:member:`event_length` is set to less than 7500 us and a PHY update to Coded PHY is performed.

| The default value of :option:`CONFIG_SDC_MAX_CONN_EVENT_LEN_DEFAULT` is 7500 us.
| The minimum event length supported by :option:`CONFIG_SDC_MAX_CONN_EVENT_LEN_DEFAULT` is 2500 us.
**Workaround:**
* Set :c:union:`sdc_cfg_t` with :c:member:`event_length` to at least 2500 us if the application is using 1M PHY.
* Set :c:union:`sdc_cfg_t` with :c:member:`event_length` to at least 7500 us if the application is using Coded PHY.

.. rst-class:: v1-6-0 v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-13594: The channel map provided by the LE Host Set Channel Classification HCI command is not always applied on the secondary advertising channels
In this case, the extended advertiser can send secondary advertising packets on channels which are disabled by the Host.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15338: Extended scanner may generate reports containing truncated data from chained advertising PDUs
The scanner reports partial data from advertising PDUs when there is not enough storage space for the full report.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15469: Slave connections can disconnect prematurely if there are scheduling conflicts with other roles
This is more likely to occur during long-running events such as flash operations.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0

DRGN-15369: Radio output power cannot be set using the vendor-specific HCI command Zephyr Write TX Power Level for all power levels
The command returns "Unsupported Feature or Parameter value (0x11)" if the chosen power level is not supported by the used hardware platform.

**Workaround** Only select output power levels that are supported by the hardware platform.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15694: An assert can occur when running an extended advertiser with maximum data length and minimum interval on Coded PHY
The assert only occurs if there are scheduling conflicts.

**Workaround** Ensure the advertising interval is configured to at least 30 milliseconds when advertising on LE Coded PHY.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15484: A connectable or scannable advertiser may end with sending a packet without listening for the ``CONNECT_IND``, ``AUX_CONNECT_REQ``, ``SCAN_REQ``, or ``AUX_SCAN_REQ``
These packets sent by the scanner or initiator can end up ignored in some cases.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15531: The coding scheme provided by the LE Set PHY HCI Command is ignored after a remote initiated PHY procedure
The PHY options set by the host in LE Set PHY command are reverted when the remote initiates a PHY update.
This happens because of the automatic reply of a PHY update Request in the SoftDevice Controller.
This makes it impossible to change the PHY preferred coding in both directions.
When receiving on S2, the SoftDevice Controller will always transmit on S8 even when configured to prefer S2.

.. rst-class:: v1-5-1 v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15758: The controller may still have pending events after :c:func:`sdc_hci_evt_get()` returns false
This will only occur if the host has masked out events.

.. rst-class:: v1-5-0 v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0

DRGN-15251: Very rare assertion fault when connected as peripheral on Coded PHY
Expand Down Expand Up @@ -1068,6 +1157,17 @@ DRGN-15382: The SoftDevice Controller cannot be qualified on nRF52832

**Workaround:** Upgrade to v1.5.1 or use the master branch.

.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-14008: The advertising data is cleared every time the advertising set is configured
This causes the "HCI LE Set Extended Advertising Parameters" command to accept data which cannot be fit within the advertising interval instead of returning "Packet Too Long (0x45)".
This would only occur if the advertising set is configured to use maximum data length on LE Coded PHY with an advertising interval less than 30 milliseconds.

.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-15291: The generation of QoS Connection events is not disabled after an HCI reset
Some event reports may still occur after a reset.

.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0

DRGN-15226: Link disconnects with reason "LMP Response Timeout (0x22)"
Expand All @@ -1094,6 +1194,33 @@ DRGN-13921: Directed advertising issues using RPA in TargetA
DRGN-10367: Advertiser times out earlier than expected
If an extended advertiser is configured with limited duration, it will time out after the first primary channel packet in the last advertising event.

.. rst-class:: v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

DRGN-11222: A Central may disconnect prematurely if there are scheduling conflicts while doing a control procedure with an instant
This bug will only be triggered in extremely rare cases.

.. rst-class:: v1-1-0 v1-0-0

DRGN-13231: A control packet may be sent twice even after the packet is ACKed
This only occurs if the radio is forced off due to an unforeseen condition.

.. rst-class:: v1-1-0 v1-0-0

DRGN-13350: HCI LE Set Extended Scan Enable returns "Unsupported Feature or Parameter value (0x11)"
This occurs when duplicate filtering is enabled.

**Workaround** Do not enable duplicate filtering in the controller.

.. rst-class:: v1-1-0 v1-0-0

DRGN-12122: ``secondary_max_skip`` cannot be set to a non-zero value
HCI LE Set Advertising Parameters will return "Unsupported Feature or Parameter value (0x11)" when ``secondary_max_skip`` is set to a non-zero value.

.. rst-class:: v1-1-0 v1-0-0

DRGN-13079: An assert occurs when setting a secondary PHY to 0 when using HCI LE Set Extended Advertising Parameters
This issue occurs when the advertising type is set to legacy advertising.

.. rst-class:: v1-1-0

:option:`CONFIG_BT_HCI_TX_STACK_SIZE` requires specific value
Expand Down Expand Up @@ -1127,10 +1254,10 @@ Sending control packet twice
A control packet could be sent twice even after the packet was acknowledged.
This would only occur if the radio was forced off due to an unforeseen condition.

.. rst-class:: v1-1-0 v1-0-0
.. rst-class:: v1-4-2 v1-4-1 v1-4-0 v1-3-2 v1-3-1 v1-3-0 v1-2-1 v1-2-0 v1-1-0 v1-0-0

Wait time required after a directed high duty cycle advertiser times out
The application is unable to restart a connectable advertiser right after a high-duty-cycle advertiser times out.
DRGN-13029: The application will not immediately restart a connectable advertiser after a high duty cycle advertiser times out
In some cases, the host may restart advertising sooner than the SoftDevice Controller is able to free its connection context.

**Workaround:** Wait 500 ms before restarting a connectable advertiser

Expand All @@ -1139,21 +1266,6 @@ Wait time required after a directed high duty cycle advertiser times out
Assert risk after performing a DLE procedure
The controller could assert when receiving a packet with a CRC error on LE Coded PHY after performing a DLE procedure where RX Octets is changed to a value above 140.

.. rst-class:: v1-1-0 v1-0-0

Assert when using HCI LE Set Extended Advertising Parameters
The controller will assert when setting secondary PHY to 0 when using HCI LE Set Extended Advertising Parameters and the advertising type is set to legacy advertising.

.. rst-class:: v1-1-0 v1-0-0

HCI issues with duplicate filtering
HCI LE Set Extended Scan Enable returns `UNSUPPORTED_FEATURE` when duplicate filtering is enabled.

.. rst-class:: v1-1-0 v1-0-0

HCI issues with `secondary_max_skip`
HCI LE Set Advertising Parameters returns `UNSUPPORTED_FEATURE` when `secondary_max_skip` is set to a non-zero value.

.. rst-class:: v1-0-0

No data issue when connected to multiple devices
Expand Down