refactor: make the mapper a little bit less cumbersome
Browse files Browse the repository at this point in the history
  • Loading branch information
mukaschultze committed Jan 24, 2024
1 parent ecaaa26 commit b536483
Show file tree
Hide file tree
Showing 5 changed files with 189 additions and 161 deletions.
40 changes: 25 additions & 15 deletions custom_components/must_inverter/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -166,7 +166,6 @@ async def connect(self):
_LOGGER.debug("connecting to %s:%s", self._client.comm_params.host, self._client.comm_params.port)

async with self._lock:
_LOGGER.debug("lock acquired")
result = await self._client.connect()

if result:
Expand All @@ -180,7 +179,6 @@ async def write_modbus_data(self, address, value):

_LOGGER.debug("writing modbus data: %s %s", address, value)
async with self._lock:
_LOGGER.debug("lock acquired")
response = await self._client.write_register(address, value, 0x04)

if response.isError():
Expand All @@ -194,34 +192,46 @@ async def write_modbus_data(self, address, value):
async def read_modbus_data(self):
_LOGGER.debug("reading modbus data")

# Reading all the control messages at once (ranges 20016-20100 and/or
# 10009-10100 are problematic) causes the inverter to shut down
# immediately and the charger stops working afterwards (all registers
# return zeroes). Requires the grid/batteries/PV to be disconnected and
# the inverter restarted for it to come back online.
registersAddresses = [
# (10001, 10, convert_partArr1),
(10101, 24, convert_partArr2),
(15201, 21, convert_partArr3),
(20001, 16, convert_partArr4),
(20101, 43, convert_partArr5),
(25201, 77, convert_partArr6),
# (10000, 10008, convert_partArr1), # Charger Control Messages
(10101, 10124, convert_partArr2), # Charger Control Messages
(15201, 15221, convert_partArr3), # Charger Display Messages
(20000, 20016, convert_partArr4), # Inverter Control Messages
(20101, 20214, convert_partArr5), # Inverter Control Messages
(25201, 25279, convert_partArr6), # Inverter Display Messages
]

read = dict()

for register in registersAddresses:
start = register[0]
end = register[1]
count = end - start + 1

try:
_LOGGER.debug("reading modbus data at address %s", register[0])
_LOGGER.debug("reading modbus data from %s to %s (%s)", start, end, count)
async with self._lock:
_LOGGER.debug("lock acquired")
response = await self._client.read_holding_registers(address=register[0], count=register[1], slave=0x04)
response = await self._client.read_holding_registers(address=start, count=count, slave=0x04)
if response.isError():
_LOGGER.error("error reading modbus data at address %s: %s", register[0], response)
elif len(response.registers) != register[1]:
_LOGGER.warn("error reading modbus data at address %s: expected %s registers, got %s", register[0], register[1], len(response.registers))
elif len(response.registers) != count:
_LOGGER.warn("wrong number of registers read at address %s, expected %s, got %s", register[0], register[1], len(response.registers))
else:
self.data.update(register[2](response.registers))
for i in range(count):
read[start + i] = response.registers[i]
self.data.update(register[2](read))
except asyncio.exceptions.CancelledError:
_LOGGER.warn("cancelled modbus read")
raise
except:
_LOGGER.error("error reading modbus data at address %s", register[0], exc_info=True)

_LOGGER.debug("finished reading modbus data")
_LOGGER.debug("finished reading modbus data, %s", read)
# _LOGGER.debug("Data: %s", self.data)

return True
Expand Down
2 changes: 1 addition & 1 deletion custom_components/must_inverter/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -26,7 +26,7 @@
# Charger Control Messages
Sensor(10101, "ChargerWorkEnable", None, None, Platform.SWITCH, None, True, None, None, None, None, None),
Sensor(10102, "AbsorbVoltage", 0.1, "V", Platform.SENSOR, SensorDeviceClass.VOLTAGE, True, None, None, None, None, None),
Sensor(20122, "FloatVoltage", 0.1, "V", Platform.NUMBER, NumberDeviceClass.VOLTAGE, True, None, None, 24.0, 29.2, 0.1 ),
Sensor(10103, "FloatVoltage", 0.1, "V", Platform.NUMBER, NumberDeviceClass.VOLTAGE, True, None, None, 24.0, 29.2, 0.1 ),
Sensor(10104, "AbsorptionVoltage", 0.1, "V", Platform.NUMBER, NumberDeviceClass.VOLTAGE, True, None, None, 24.0, 29.2, 0.1 ),
Sensor(10105, "BatteryLowVoltage", 0.1, "V", Platform.NUMBER, NumberDeviceClass.VOLTAGE, True, None, None, 20.0, 24.0, 0.1 ),
Sensor(10107, "BatteryHighVoltage", 0.1, "V", Platform.SENSOR, SensorDeviceClass.VOLTAGE, True, None, None, None, None, None),
Expand Down
Loading

0 comments on commit b536483

Please sign in to comment.