Skip to content

battery warning level for FreeBSD control method batteries.

Notifications You must be signed in to change notification settings

random532/FreeBSD_Battery_Trip_Point

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

57 Commits
 
 
 
 
 
 
 
 

Repository files navigation

FreeBSD Battery Warnings

Affected file:
sys/dev/acpica/acpi_cmbat.c


Short description:
You don't need to poll the battery periodically.
You can set a percentage (ranging from 0-100) via sysctl.
This causes a /dev/devd event Notify(0x80). So a script can be triggered.

Long description:
ACPI specification defines an optional acpi method called "_BTP".
Currently the FreeBSD cmbat driver only supports mandatory methods (bif, bix, ..), but no optional ones.

Try the command: "acpidump -dt |grep _BTP". If it returns something, your battery supports this function.

If supported by the battery, a new sysctl is created: dev.battery.X.Warning_Level
Replace the X with your battery index (0, 1, ...).

You can set the warning level ("trip point") with this sysctl (values between 0-100 are allowed).
If the battery reaches that percentage, devd will be notified.

Add an entry in /etc/devd.conf:
notify 10 {
match "system" "ACPI";
match "subsystem" "CMBAT";
action "/home/myuser/myscript.sh $notify";
};

Replace myuser with your local user. Replace myscript.sh with a script of your choice.

Personal note: If you have any questions, please write me. I will look at this again.
Thanks. :-)

Installation guide for beginners:

Step 1: Try the command: "acpidump -dt |grep _BTP". If it returns something, your battery supports this function.

Step 2: Donwload the Freebsd source code.
Replace the file from this repo with the file /usr/src/sys/dev/acpica/acpi_cmbat.c

Step 3: Build and install the new kernel.

Step 4: Add an entry in /etc/devd.conf:
notify 10 {
match "system" "ACPI";
match "subsystem" "CMBAT";
action "/home/myuser/myscript.sh $notify";
};

Step 5: Replace mysuser and myscript with an actual user and an actual script.

Step 6: Set the sysctl dev.battery.0.Warning_Level to your desired warning level. If it works, give me feedback.