simulation of a labscale 1-1 shell and tube heat exchanger water/water in OpenFoam.
-
$U_{inlet shell}$ = 0.2 m/s; -
$U_{inlet tubes}$ = 0.02 m/s; -
$T_{inlet shell cold}$ = 283K; -
$T_{inlet tubes hot}$ = 383K; $configuration = co-current$ -
$baffle-pitch = shell-diameter$ ; -
$baffle-cut = 0.25$ ;
-
$U_{outlet shell}$ = 0.2 m/s; -
$U_{outlet tubes}$ = 0.02 m/s; -
$T_{outlet shell cold}$ = 286K; -
$T_{outlet tubes hot}$ = 360K;