The project required the computation of the Line Outage Distribution Factors (LODF) based on a user given branch outage number using the fast-decoupled XB version. The LODF values were used to approximate the post-contingency branch flows based on a pre-contingency branch flow and the base branch flow before the contingency. The AC power flows w…
matlab
power-systems-analysis
power-flow
contingency
power-system-simulation
branch-flow
outage-distribution-factors
branch-outages
mva-flows
lodf-factors
lodf-values
-
Updated