Add modern configuration options for NodOn SIN-4-1-20, SIN-4-1-21, SIN-4-2-20, and alike #3568

Open
wants to merge 7 commits into
base: dev
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
110 changes: 109 additions & 1 deletion zhaquirks/nodon/switch.py
Original file line number Diff line number Diff line change
@@ -1,14 +1,122 @@
"""NodOn on/off switch two channels."""

from zigpy.quirks import CustomCluster
from zigpy.quirks.v2 import QuirkBuilder
from zigpy.zcl.clusters.general import LevelControl
from zigpy.quirks.v2.homeassistant import UnitOfTime
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass
import zigpy.types as t
from zigpy.zcl.clusters.general import LevelControl, OnOff
from zigpy.zcl.foundation import DataTypeId, ZCLAttributeDef

NODON = "NodOn"


class NodOnSwitchType(t.enum8):
"""NodOn switch type."""

Bistable = 0x00
Monostable = 0x01
AutoDetect = 0x02


class OnOffSIN4_1_20(OnOff, CustomCluster):
"""NodOn custom OnOff cluster for SIN-4-1-20 and alike."""

class AttributeDefs(OnOff.AttributeDefs):
"""Attribute definitions."""

"""Select the switch type wire to the device. Available from version > V3.4.0."""
switch_type = ZCLAttributeDef(
id=0x1001,
type=NodOnSwitchType,
zcl_type=DataTypeId.enum8, # need to explicitly set ZCL type
access="rw",
is_manufacturer_specific=True,
)

""" Set the impulse duration in milliseconds (set value to 0 to deactivate the impulse mode). """
impulse_mode_duration = ZCLAttributeDef(
id=0x0001,
type=t.uint16_t,
access="rw",
is_manufacturer_specific=True,
)


class OnOffSIN4_2_20(OnOff, CustomCluster):
"""NodOn custom OnOff cluster for SIN-4-2-20 and alike."""

class AttributeDefs(OnOff.AttributeDefs):
"""Attribute definitions."""

"""Select the switch type wire to the device. Available from version > V3.4.0."""
switch_type = ZCLAttributeDef(
id=0x1001,
type=NodOnSwitchType,
zcl_type=DataTypeId.enum8, # need to explicitly set ZCL type
access="rw",
is_manufacturer_specific=True,
)


(
# quirk is similar to https://github.com/Koenkk/zigbee-herdsman-converters/blob/master/src/devices/nodon.ts#L100
QuirkBuilder(NODON, "SIN-4-1-20")
.applies_to(NODON, "SIN-4-1-21")
.applies_to(NODON, "SIN-4-1-20_PRO")
# .filter() TODO this should be applied to firmware 3.4.0+, but I didn't find a way to reliably detect it .
# Please let me know if you know how
.replaces(OnOffSIN4_1_20)
.enum(
attribute_name=OnOffSIN4_1_20.AttributeDefs.switch_type.name,
enum_class=NodOnSwitchType,
cluster_id=OnOffSIN4_1_20.cluster_id,
initially_disabled=True,
translation_key="switch_type",
fallback_name="Switch type",
)
.number(
attribute_name=OnOffSIN4_1_20.AttributeDefs.impulse_mode_duration.name,
cluster_id=OnOffSIN4_1_20.cluster_id,
min_value=0,
max_value=10000,
step=1,
unit=UnitOfTime.MILLISECONDS,
device_class=NumberDeviceClass.DURATION,
initially_disabled=True,
translation_key="impulse_mode_duration",
fallback_name="Impulse mode duration",
)
.add_to_registry()
)

(
# this quirk is a v2 version of 7397b6a
QuirkBuilder(NODON, "SIN-4-2-20")
.applies_to(NODON, "SIN-4-2-20_PRO")
.removes(cluster_id=LevelControl.cluster_id, endpoint_id=1)
.removes(cluster_id=LevelControl.cluster_id, endpoint_id=2)
# .filter() TODO this should be applied to firmware 3.4.0+, but I didn't find a way to reliably detect it .
# Please let me know if you know how
.replaces(OnOffSIN4_2_20, endpoint_id=1)
.replaces(OnOffSIN4_2_20, endpoint_id=2)
.enum(
attribute_name=OnOffSIN4_1_20.AttributeDefs.switch_type.name,
enum_class=NodOnSwitchType,
cluster_id=OnOffSIN4_1_20.cluster_id,
endpoint_id=1,
initially_disabled=True,
translation_key="switch_type",
fallback_name="Switch type",
)
.enum(
attribute_name=OnOffSIN4_1_20.AttributeDefs.switch_type.name,
enum_class=NodOnSwitchType,
cluster_id=OnOffSIN4_1_20.cluster_id,
endpoint_id=2,
initially_disabled=True,
translation_key="switch_type",
fallback_name="Switch type",
)
.add_to_registry()
)